Bell Wire

 

Diagnostics

 

Located On

 

Motor Unit

 

LED or

 

Diagnostic

 

LED

 

"Learn"

Safety Reversing Sensor

Button

Diagnostic Chart

Installed

Safety Reversing

Sensor

Your garage door opener is programmed with self-diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below.

1 FLASH

Symptom: One or both of the Indicator lights on the safety sensors do

 

 

not glow steady.

Safety Reversing Sensors

• Inspect sensor wires for a short (staple in wire), correct wiring polarity

wire open (broken or

(black/white wires reversed), broken or disconnected wires, replace/attach

disconnected).

as needed.

 

OR

• Disconnect all wires from back of motor unit.

2

FLASHES

• Remove sensors from brackets and shorten sensor wires to 1-2 ft. (30-60 cm)

 

 

from back each of sensor.

Safety Reversing

• Reattach sending eye to motor unit using shortened wires. If sending eye

indicator light glows steadily, attach the receiving eye.

Sensors wire shorted or

• Align sensors, if the indicator lights glow replace the wires for the sensors. If

black/white wire

reversed.

the sensor indicator lights do not light, replace the safety sensors.

3

FLASHES

Symptom: LED is not lit on door control.

Door control or

• Inspect door control/wires for a short (staple in wire), replace as needed.

• Disconnect wires at door control, touch wires together. If motor unit activates,

wire shorted.

replace door control.

 

 

 

 

• If motor unit does not activate, disconnect door control wires from motor unit.

 

 

Momentarily short across red and white terminals with jumper wire. If motor

 

 

unit activates, replace door control wires.

4

FLASHES

Symptom: Sending indicator light glows steadily, receiving indicator light

 

 

is dim or flashing.

 

 

Safety Reversing Sensors

• Realign receiving eye sensor, clean lens and secure brackets.

slightly misaligned

• Verify door track is firmly secured to wall and does not move.

(dim or flashing LED).

 

 

 

 

5

FLASHES

Symptom: Motor has over heated; the motor unit does not operate or

 

 

trolley is stuck on stop bolt = Motor unit hums briefly; RPM Sensor =

Motor overheated or

Short travel 6-8" (15-20 cm).

possible RPM sensor

• Unplug unit to reset. Try to operate motor unit, check diagnostic code.

failure. Unplug to reset.

• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM

 

 

 

 

sensor.

 

 

• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and

 

 

retry. If motor unit still will not operate replace logic board.

6

FLASHES

Symptom: Motor unit doesn’t operate.

Motor Circuit Failure.

• Replace logic board because motor rarely fails.

 

Replace Receiver

 

Logic Board.

 

30