PROGRAMMING THE REMOTE TO THE

Figure 4

RECEIVER

 

 

 

 

With Security®, the code between the remote control and the receiver changes with each use, accessing over 100 billion new codes.

You can activate your opener with up to 8 Security® remote controls and one Security® Keyless Entry.

1.

Pry open the front panel of receiver case with a coin or a

 

 

screwdriver (Figure 4). Re-connect power to opener.

 

2.

Press and release the “SMART” button on the receiver. The

 

 

“SMART” indicator light will glow steadily for 30 seconds

 

 

(Figure 5).

 

3.

Within 30 seconds, press and hold the button on the

Figure 5

 

hand-held remote that you wish to operate your garage door

(Figure 6).

3

2

1

 

®

The opener will now operate when the push button on either the

Indicator

 

receiver or the remote control is pressed.

Light

 

Figure 6

 

P2

Repeat Steps 2 and 3 for each remote control that will be used

“SMART”

C

M

to operate the garage door opener.

Button

 

 

Option

C

 

P2

TO ERASE ALL REMOTE CONTROL CODES

Jumper

M

 

 

Press and hold the “SMART” button on the receiver panel until the indicator light turns off (about 6 seconds). All remote control codes are now erased. Then follow the steps above to reprogram each remote control.

REPLACING THE REMOTE

CONTROL BATTERY

The lithium battery should produce power for up to 5 years. To replace battery, pry open case with visor clip or screwdriver, as shown. Insert battery positive side up. Dispose of old battery properly.

SET OUTPUT DURATION (COMMERCIAL APPLICATIONS ONLY)

WARNING

To prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED.

For commercial applications, the receiver can be set for either constant or momentary closure on the output contacts. Use of constant closure is prohibited on residential garage door openers because it overrides the safety reversal devices.

With the jumper in the “M” (Momentary) position, the contacts will close for 1/4 second regardless of the length of radio transmission. With the jumper in “C” (Constant) position, the contacts will stay closed as long as the radio continues transmitting.

The receiver is factory set at M.

 

SPECIFICATIONS

Output Rating......................................

5 Amps 28VAC or DC Max.

Power ....................................................

18V - 30V ~, 30mA, 60Hz

 

18 - 30V

 

 

 

 

, 30mA

 

 

 

 

 

 

 

 

RF Frequency....................................................................

 

315MHz

If the power is other than shown in specifications, Accessory Transformer Model 85 or 95 is required.

Accessory Remote Controls — Series 300.

WARNING

To prevent possible SERIOUS INJURY or DEATH:

NEVER allow small children near batteries.

If battery is swallowed, immediately notify doctor.

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or remote control are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

MOMENTARY

Jumper

 

OPERATION

 

 

Output

 

 

Duration

 

 

Terminals

CONSTANT

Jumper

 

OPERATION

 

 

M

 

 

Output

 

 

Duration

 

Terminals

M

FOR SERVICE DIAL OUR TOLL FREE NUMBER: 1-800-528-2817

 

©2006 The Chamberlain Group, Inc.

114A3099D