Bell Wire |
|
| Diagnostics |
| Located On |
| Motor Unit |
| LED or |
| Diagnostic |
| LED |
| "Learn" |
Safety Reversing Sensor | Button |
Installed



Safety Reversing
Sensor
Your garage door opener is programmed with
1 FLASH | Symptom: One or both of the Indicator lights on the safety sensors do not | ||
| Safety reversing sensors | glow steady. | ||
• Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/white | |||
| wire open (broken or | |||
wires reversed), broken or disconnected wires, replace/attach as needed. | |||
| disconnected). | • Disconnect all wires from back of motor unit. | ||
| OR | ||
| • Remove sensors from brackets and shorten sensor wires to | ||
2 | FLASHES | from back each of sensor. | |
• Reattach sending eye to motor unit using shortened wires. If sending eye indicator | |||
|
| ||
Safety reversing sensors | light glows steadily, attach the receiving eye. | ||
• Align sensors, if the indicator lights glow replace the wires for the sensors. If the | |||
| wire shorted or black/ | |||
| white wire reversed. | sensor indicator lights do not light, replace the safety sensors. | ||
3 | FLASHES | Symptom: LED is not lit on door control. | |
| Door control or | • Inspect door control/wires for a short (staple in wire), replace as needed. | ||
• Disconnect wires at door control, touch wires together. If motor unit activates, | |||
| wire shorted. | |||
replace door control. | |||
|
| ||
|
| • If motor unit does not activate, disconnect door control wires from motor unit. | |
|
| Momentarily short across red and white terminals with jumper wire. If motor unit | |
|
| activates, replace door control wires. | |
4 | FLASHES | Symptom: Sending indicator light glows steadily, receiving indicator light is | |
|
| dim or flashing. | |
Safety reversing sensors | |||
• Realign receiving eye sensor, clean lens and secure brackets. | |||
| slightly misaligned | |||
• Verify door track is firmly secured to wall and does not move. | |||
| (dim or flashing LED). | |||
| |||
5 | FLASHES | Symptom: Motor has over heated; the motor unit does not operate or trolley is |
|
| stuck on stop bolt = Motor unit hums briefly; RPM Sensor = |
|
| |
| Motor overheated or | Short travel | |
| possible RPM sensor | • Unplug unit to reset. Try to operate motor unit, check diagnostic code. | |
| failure. Unplug to reset. | • If it is still flashing 5 times and motor unit moves | |
|
| |
|
| RPM sensor. |
|
| • If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and retry. |
|
| If motor unit still will not operate replace logic board. |
6 | FLASHES | Symptom: Motor unit doesn’t operate. | |
| Motor Circuit Failure. | • Replace logic board because motor rarely fails. | ||
| |||
| Replace Receiver |
| ||
| Logic Board. |
| ||