MOUNTING AND WIRING THE SAFETY REVERSING | Figure 5 | |
SENSORS |
| |
• | Slide a | Wing Nut |
| each sensor. Use wing nuts to fasten sensors to | |
|
| |
| brackets, with lenses pointing toward each other across |
|
| the door. Be sure the lens is not obstructed by a bracket |
|
| extension (Figure 5). | Carriage Bolt |
|
| |
• | Finger tighten the wing nuts. | |
Lens |
•Run the wires from both sensors to the opener. Use
| insulated staples to secure wire to wall and ceiling. | TROUBLESHOOTING THE SAFETY REVERSING | |
• Strip 7/16" (11 mm) of insulation from each set of wires. | |||
SENSORS | |||
| Separate white and white/black wires sufficiently to | 1. If the sending eye indicator light does not glow steadily | |
| connect to the opener | ||
| after installation, check for: | ||
| like colored wires together. Insert wires into quick- | ||
| • Electric power to the opener. | ||
| connect holes: white to white and white/black to grey | ||
| • A short in the white or white/black wires. These can | ||
| (Figure 6). | ||
ALIGNING THE SAFETY REVERSING SENSORS | occur at staples, or at opener connections. | ||
• Incorrect wiring between sensors and opener. | |||
• | Plug in the opener. The indicator lights in both the | ||
• A broken wire. | |||
| sending and receiving eyes will glow steadily if wiring | ||
| 2. If the sending eye indicator light glows steadily but the | ||
| connections and alignment are correct. | ||
| receiving eye indicator light doesn’t: | ||
The sending eye amber indicator light will glow regardless | |||
• Check alignment. | |||
of alignment or obstruction. If the green indicator light in | |||
• Check for an open wire to the receiving eye. | |||
the receiving eye is off, dim, or flickering (and the invisible | |||
light beam path is not obstructed), alignment is required. | 3. If the receiving eye indicator light is dim, realign either | ||
|
| ||
• | Loosen the sending eye wing nut and readjust, aiming | sensor. | |
| directly at the receiving eye. Lock in place. | NOTE: When the invisible beam path is obstructed or | |
• | Loosen the receiving eye wing nut and adjust sensor | misaligned while the door is closing, the door will reverse. | |
| until it receives the sender’s beam. When the green | If the door is already open, it will not close. The opener | |
| indicator light glows steadily, tighten the wing nut. | lights will blink 10 times. See page 16. |
Figure 6 | Connect Wire to |
|
|
Opener |
|
| |
Bell Wire | Finished |
|
|
Ceiling |
|
| |
| 1. | Strip wire 7/16" | |
| Bell Wire | (11 mm) | 7/16" |
| (11mm) | ||
|
|
| |
| 2. | Twist like colored | |
|
| wires together | |
| 3. To release or insert | ||
|
| wire, push in tab with | |
|
| screwdriver tip |
Red White Grey
Safety Reversing Sensor
Invisible Light Beam
Protection Area
Safety Reversing Sensor
18