ASSEMBLY STEP 3

Attach the Belt Cap Retainer

Position the belt cap retainer over the motor unit belt pulley so the three holes in cap align with the three holes in mounting plate. Attach with #8x3/8" hex screws provided.

You have now finished assembling your garage door opener. Please read the following warnings before proceeding to the installation section.

HARDWARE SHOWN

ACTUAL SIZE

Hex Screw

#8x3/8"

WARNING

To avoid possible SERIOUS INJURY to fingers from moving garage door opener:

ALWAYS keep hand clear of belt pulley while operating opener.

Securely attach belt pulley cover BEFORE operating.

8x3/8" Hex Screws

Belt Cap Retainer

Motor Unit Belt Pulley

Mounting Plate

INSTALLATION

IMPORTANT INSTALLATION INSTRUCTIONS

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

1.READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.

2.Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH.

3.ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.

4.Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.

5.Install garage door opener 7 feet (2.1 m) or more above floor.

6.Mount emergency release handle 6 feet (1.8 m) above floor.

7.NEVER connect garage door opener to power source until instructed to do so.

8.NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.

9.Install wall-mounted garage control console:

within sight of the garage door.

out of reach of children at minimum height of 5 feet (1.5 m).

away from ALL moving parts of the door.

10.Place entrapment warning label on wall next to garage control console.

11.Place manual release/safety reverse test label in plain view on inside of garage door.

12.Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.

13.To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric and battery power BEFORE performing ANY service or maintenance.

7