INSTALLATION STEP 7

Install the Light and Lens

INSTALL THE LIGHT

Install a 75 watt maximum light bulb in each socket. The light will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the light will turn OFF.

If the bulbs burn out prematurely due to vibration, replace with a Garage Door Opener bulb.

INSTALL THE LENS

Locate and loosen (approximately 1/8") the two screws near top of motor unit front panel. Position lens against panel with slotted tabs directly below screws. Slide lens up to seat tabs behind screws. Snap bottom tabs of lens into panel slots. Retighten top panel screws to secure lens.

NOTE: Use only standard light bulbs. The use of short neck or speciality light bulbs may overheat the endpanel or light socket.

Screw

Light

Panel

Lens

 

 

Lens Slot

 

75 Watt Max.

 

Light Bulb

 

Lens Tab

INSTALLATION STEP 8

Attach the Emergency Release Rope and Handle

Thread one end of the rope through the hole in the top of the red handle so "NOTICE" reads right side up as shown. Secure with an overhand knot at least 1" from the end of the rope to prevent slipping.

Thread the other end of the rope through the hole in the release arm of the outer trolley.

Adjust rope length so the handle is 6 feet above the floor. Secure with an overhand knot.

NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.

WARNING

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:

If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.

NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.

NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.

Overhand

Knot

Trolley

 

Trolley

 

Rope

Release Arm

 

 

Emergency

Release Handle

15