I N S T A L L A T I O N

POST MOUNTING (SW470)

Figure 1

 

1.Locate and anchor two posts made of 3" (7.6 cm) outer diameter heavy walled pipe. Posts should be parallel and square to the gate.

IMPORTANT NOTE: The distance between mounting posts and the relative location of the operator to the gate and fence is critical.

2.Locate electrical conduit, as required, prior to pouring concrete.

3.Set mounting post and electrical conduit in place (Figure 2). Knockouts for 3" pipe clamps (not supplied) are provided in the operator.

18.5"

Figure 2

3" U-bolt (4 required)

Fence

30"

9.5"

23"

3" O.D. pipe

 

(2 req’d.)

 

 

Concrete pad

16 x 32 minimum

 

Operator

 

Parallel Mount

 

Fence

 

20"

 

3" O.D. pipe

 

(2 req’d.)

23"

Concrete pad

 

16 x 32 minimum

 

Operator

Perpendicular Mount

Power and control wiring should be run in separate conduit

9