USE

Minimum & Maximum Records

The display unit features Minimum & Maximum records display mode. The minimum and maximum values for indoor and outdoor temperature and humidity are recorded and kept until midnight every day, when the records are reset for the next day.

Minimum Records

To view the minimum records, touch the “adjust down” button ( ) located on the front of the display unit. The minimum recorded values will display for about 8 seconds (note the “MIN” icon indicating minimum records being displayed). To manually reset the records being displayed, touch and hold the “adjust down” ( ) button while viewing the records.

Maximum Records

To view the maximum records, touch the “adjust up” button ( ) located on the front of the display unit. The maximum recorded values will display for about 8 seconds (note the “MAX” icon indicating maximum records being displayed). To manually reset the records being displayed, touch and hold the “adjust up” ( ) button while viewing the records.

Momentary Backlight

The display unit features a momentary blue backlight for easy night-time viewing. The touch button to activate the backlight is located on the top portion of the display bezel. Touching the button will give you about 5 seconds of illumination. Note that excessive use of the backlight will reduce the battery life.

TROUBLESHOOTING

 

 

 

 

 

 

 

 

Problem

 

Possible Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relocate the main unit and/or the wireless

 

 

 

 

 

 

 

 

Bad

sensor. Both units must be within 330 feet

 

 

 

 

 

 

 

 

(100m) from each other. Make sure both

 

 

 

 

Wireless Sensor

units are placed at least 3 feet (.91 m) from

 

 

 

 

 

 

Reception

other electronic appliances and devices that

 

 

 

 

 

 

may interfere with the wireless

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

communication (such as TVʼs, microwaves,

 

 

 

 

 

 

 

 

 

 

 

computers etc). NOTE: It may take up to 20

 

 

 

 

 

 

 

 

no bars

minutes for the main unit to re-synchronize

 

 

 

 

 

 

 

 

with the sensor when batteries are replaced.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use lithium batteries in sensor when

 

 

 

 

 

 

 

 

 

 

 

temperature is below -4ºF (-20ºC).

 

 

 

 

 

 

 

 

 

 

 

 

No Wireless Sensor Data

If wireless reception is bad (no bars), see

 

 

(no communication)

“Bad Reception” section above. The wireless

 

 

 

 

no bars and flashing

ID setting on each unit must match for all

 

 

 

 

units to communicate properly. See “Set

 

 

 

 

 

 

 

 

 

 

 

 

-- ” data

Wireless ID” on the next page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display Console

Make certain that the batteries are installed

 

 

 

 

correctly.

 

 

Screen Not Working

Batteries may need replacing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please DO NOT return product to the retail store.

For technical assistance and product return information, please call Customer Care: 877-221-1252M-F7:00 A.M. to 7:00 P.M. (Central)

www.chaneyinstrument.com

7

8

Page 5
Image 5
Chaney Instrument 13230 warranty Minimum & Maximum Records, Momentary Backlight, Troubleshooting

13230, 13230 specifications

The Chaney Instrument 13230 is a sophisticated device renowned for its accuracy and reliability in measuring environmental conditions. As a digital thermometer and hygrometer, it is designed to provide precise readings of temperature and humidity, making it an essential tool for both amateurs and professionals in various fields, such as agriculture, meteorology, and HVAC systems.

A standout feature of the Chaney Instrument 13230 is its dual display, which allows users to view both temperature and humidity levels simultaneously. This user-friendly interface simplifies data reading and enhances usability. The instrument offers a temperature measurement range from -20 to 120 degrees Fahrenheit, with an accuracy of ±1 degree. Its hygrometer measures relative humidity from 1% to 99%, ensuring that users get reliable readings across a wide spectrum of conditions.

The Chaney Instrument 13230 employs advanced sensor technology, which contributes to its high level of accuracy and reliability. The digital sensor technology minimizes the potential for errors that can occur with mechanical sensors, making it particularly advantageous for those who require consistent and precise environmental monitoring.

Another notable characteristic of the Chaney Instrument 13230 is its compact and portable design. This allows users to easily transport the instrument to various locations, facilitating the collection of data in different environments. The built-in memory function stores past readings, enabling users to analyze trends and changes over time without the need for additional record-keeping.

The device also features a convenient battery-operated power source, which enhances its portability and ease of use. With minimal power consumption, the Chaney Instrument 13230 ensures extended operation, making it suitable for long-term monitoring and fieldwork.

In conclusion, the Chaney Instrument 13230 combines advanced technology with practical functionality. Its dual display, wide measurement range, and user-friendly features make it an invaluable tool for those in need of reliable temperature and humidity readings. Whether it's for professional use, scientific research, or personal hobbies, the Chaney Instrument 13230 stands out as a leading choice for environmental monitoring. The blend of accuracy, portability, and advanced sensor technology ensures that users can depend on this instrument for their specific needs.