Hold coupling nut and regulator

as shown for proper connection

to LP cylinder valve.

6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the

connection, do not use this regulator!

Leak Testing Valves, Hose and Regulator

1.Turn all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto areas circled below.

DANGER

Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.

WARNING

Outdoor gas appliance is not intended to be installed in or on a boat.

Outdoor gas appliance is not intended to be installed in or on an RV.

Never attempt to attach this grill to the self-contained LP gas system of a camper trailer or motor home.

Do not use grill until leak-tested.

If a leak is detected at any time, STOP and call the fire department.

If you cannot stop a gas leak, immediately close LPcylinder valve and call LP gas supplier or your fire department!

NOTE: Sideburner

shelf fascia not

shown for clarity.

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by giving the serial, model number and name and part number of items needed (see parts list) to the Grill Service Center at 1-800-241-7548.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

6 • 463271108