knobisturned.
Beforeinitiallightingthefollowing
pointsshouldbechecked:-
1.Thebottomgratebarsmustallbe
fittedandshouldmovefreelyand
easilywhentheriddlingmechanismis
operated.
2.Theplatesroundthesidesandback
ofthegratemustbeinpositionand
sittingcorrectly.
3.Thethroatplatemustbefittedinthe
PRELIGHTINGCHECK
roofoftheapplianceandshouldbe
checkedtoensurethatithasnot
becomedislodgedintransit.The
methodoflocationandpositioningof
thethroatplateisshowninFig.3.
Oncompletionoftheinstallationand
afterallowingasuitableperiodoftime
forthefirecementandmortartodry
out,thestoveshouldbelitand
checkedtoensurethatsmokeand
fumesaretakenfromtheapplianceup
thechimneyandemittedsafely.Also
checkalljointsandseals.
Thecentralheatingpumpshouldbe
COMMISSIONING
adjustedtogivethecorrectwaterflow
againstthecircuitresistanceandthe
systemshouldbecorrectlybalanced.
Oncompletionoftheinstallationand
commissioningpleaseleavethe
operatinginstructionswiththe
customerandadviseontheuseofthe
applianceandanycontrolsonthe
system.
389
655
616 334
Ø154
882
340
857
487
937
815
136
45
Country15BDimensions
(Alldimensionsareinmm)
Boilertappingsare1"BSPFemale
Flueoutletmaybetoporrear
Page8
Country15B09/03