3.SETUP
Disconnect the power cord before replacing a fuse, and always replace with the same type fuse.
Fuse Replacement
With a Phillips #2 screwdriver, unscrew the fuse holder from its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its place and reconnect power.
The fuse is located inside this compartment. Remove using a Phillips #2 screwdriver.
FUSE
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a
Important: | Fixtures on a serial data link must be daisy chained in one single line. To comply with |
| the |
| link. Connecting more than 32 fixtures on one serial data link without the use of a |
| DMX |
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use
DMX D AT A C ABLE
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA
Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor and shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms