AC Plug

EN

COLORdash™ Par-Tri 18VW QRG

AC Power This product has an auto-ranging power supply that can work with an input voltage range of 100~240 VAC, 50/60 Hz.

Power Linking You can link up to 15 COLORdash™ Par-Tri 18VW products at 120 VAC or 28 at 230 VAC. Never exceed this number. Power linking cords can be purchased separately.

AC Plug

 

Connection

Wire (U.S.)

Wire (Europe)

Screw Color

 

 

AC Live

Black

Brown

Yellow/Brass

 

 

AC Neutral

White

Blue

Silver

Fuse

 

AC Ground

Green/Yellow

Green/Yellow

Green

1.

Disconnect this

product from power.

 

Replacement

2.

Using a flat-head screwdriver, unscrew the fuse holder cap from the

 

 

housing.

 

 

 

3.Remove blown fuse and replace with a good fuse of the same type and rating.

4.Screw the fuse holder cap back in place and reconnect power.

DMX Linking The COLORdash™ Par-Tri 18VW will work with a DMX controller using a regular DMX serial connection. A DMX Primer is available from www.chauvetpro.com.

DMX Connection The COLORdash™ Par-Tri 18VW uses a regular DMX data connection for its DMX personalities: 2 Ch, 3 Ch, and 7 Ch. See the User Manual to connect and configure for DMX operation.

Master/Slave The COLORdash™ Par-Tri 18VW uses the DMX data connection for its Connection Master/Slave mode. See the User Manual to connect and configure for