OPERATION

B-3

LN-25™ INSTRUMENTS AND

NOTE:

 

CONTROLS

 

 

1. The Voltmeter will read zero if the LN-25™ work

 

 

 

Refer to Figure B.1 for control locations.

clip lead is not connected to work, even if the

electrode is electrically “hot” to work.

 

 

 

 

 

FIGURE B.1 – CONTROL LOCATIONS.

2. The Voltmeter will read below zero if the LN-25™

 

 

 

polarity switch is not set to the same polarity as

REMOTE

WIRE SPEED

the electrode.

 

ARC VOLTAGE

DIAL RANGE

3. The Voltmeter will read power source open circuit

CONTROL

SWITCH

(OPTIONAL)

 

 

voltage when the gun trigger is open, even if the

 

 

 

 

 

WIRE

LN-25™ is equipped with the internal contactor.

 

 

 

 

 

 

SPEED

“ELECTRODE POLARITY” SWITCH

 

 

 

DIAL

 

 

 

VOLT

The polarity switch is located on the front panel of the

GAS POST/

 

LN-25™ case.

 

 

METER

 

 

 

 

PRE FLOW

 

 

Set the switch to the same polarity as the electrode

TIMERS

 

 

(OPTIONAL)

 

 

lead connection to the power source. If the switch is

 

 

 

ELECTRODE

 

 

not set for the correct polarity, the wire feeder will not

 

 

operate.

 

POLARITY

 

WORK CLIP

 

 

 

 

SWITCH

 

 

 

 

LEAD

WIRE FEED MODE SWITCH

 

 

 

 

GAS

 

 

 

 

 

 

 

FITTING

 

GUN

 

 

(OPTIONAL)

 

CONNECTION

The CV-VV (CC) Wire Feed Mode switch is located

GUN

 

BLOCK

inside the LN-25™ case. The toggle switch extends

 

 

TRIGGER

 

 

from beneath the control box just above the wire drive.

AMPHENOL

 

 

 

 

CONNECTOR

 

 

The forward “CV” position provides constant wire feed

 

 

 

 

 

 

speed mode for use with constant voltage (CV)

 

 

 

welding power sources.

 

 

 

 

The backward “VV (CC)” position provides arc-sensing

 

 

 

wire feed speed mode for use with constant current

 

 

 

(formerly variable voltage) welding power sources.

 

 

OPTIONAL

 

 

 

 

 

 

 

 

GAS INPUT

WIRE SPEED DIAL AND RANGE SWITCH

 

 

 

 

 

 

 

 

 

FITTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to

Return

GAS PURGE BUTTON

The Wire Speed control dial on the front panel of the LN-25™ has two calibrated dial ranges selected by the HI-LO Dial Range switch.

When switched to the LO range position, the constant wire feed speed (CV Wire Feed Mode) is set on the inside (white) dial range calibrated for 50 to 350 in/min.

Return to Section TOC

Return to Master TOC

ELECTRODE

CABLE

VOLTMETER

(Factory installed on model Codes above 9218)

The 40V DC analog voltmeter is mounted to the front control panel of the LN-25™ and is connected to read the arc voltage between the LN-25™ electrode cable connection and the work clip lead.

When switched to the HI range position, the constant wire feed speed (CV Wire Feed Mode) is set on the outside (black) dial range calibrated for 50 to 700 in/min.

The volts marks around the HI range calibrated dial indicate the minimum arc volts required to obtain the indicated HI range wire feed speeds. For example; if wire speed is set to 400 in/min., a welding procedure arc voltage of at least 17V would be required to obtain the 400 in/min. wire feed speed.

LN-25™