RETEST AFTER REPAIR

If a failed test indicates that any mechanical part that could affect the machine’s electrical characteristics must be replaced or if any electrical components are repaired or replaced, the machine must be retested and meet the following standards.

Wire Feed Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50 through 700 Inches Per Minute

Voltmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Must be operative from 0 through 40 VDC

Gas Solenoid (optional) . . . . . . . . . . . . . . . . . . . . . .

Must operate when gun trigger is activated

Contactor (optional) . . . . . . . . . . . . . . . . . . . . . . . . . .

Must operate when gun trigger is activated