Lincoln Electric SVM114-C GAS Solenoid Valve and Solenoid PC Board Test, Test Description

Models: SVM114-C

1 111
Download 111 pages 23.31 Kb
Page 45
Image 45

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

TROUBLESHOOTING AND REPAIR

F-7

GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST

(FOR CODES BELOW 10500 ONLY)

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This test will determine if the gas solenoid valve or the solenoid PC board are functional.

MATERIALS NEEDED

Phillips Head Screwdriver 12 VDC Supply Volt/Ohmmeter

DC Voltage Source (25 to 100 VDC)

LN-25™

Page 45