MAINTENANCE

D-2

 

 

 

CONTROL BOX

 

 

SAFETY PRECAUTIONS

 

 

 

 

 

 

 

 

Every six months open and inspect the control sec-

 

 

 

 

WARNING

 

 

 

 

 

 

tion. The accumulated dirt should be gently blown off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

 

all of the electrical components. Be sure the air that

 

 

 

 

is being used is dry. Check that lead plugs are secure

 

 

 

• Do not operate with covers

 

in their receptacles.

 

 

 

 

 

 

 

removed.

WIRE DRIVE MOTOR AND GEARBOX

Return to Section TOC

Return to Master TOC

Turn off power source before installing or servicing.

Do not touch electrically hot parts.

Turn the input power to the welding power source off at the fuse box before working in the terminal strip.

Only qualified personnel should install, use or service this equipment.

Every year examine the gearbox. Paint the gear teeth with molydisulfide filled grease. Do not use a graphite grease.

Check the motor brushes. Replace if they are worn down to 14’’ or less. When ordering feed motor brushes, give all information from the motor nameplate.

GUN AND CABLE MAINTENANCE

See IM manual provided with the gun and cable as- sembly.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

ROUTINE MAINTENANCE

DRIVE ROLLS AND GUIDE TUBES

After feeding every coil of wire, inspect the drive roll section. Clean it as necessary. Do not use a solvent for cleaning the idle roll because it may wash the lu - bricant out of the bearing. The drive roll, idle roll and guide tubes are stamped with the wire sizes they will feed. If a wire size other than that stamped on the rolls is to be used, the rolls and guide tubes must be changed.

The drive rolls for .035 through .052 cored electrode and 116 through 564 electrode have a double set of teeth so they can be reversed for additional life. Drive rolls for .023 through .052 solid electrode and aluminum sizes have no teeth but use two grooves so they also can be reversed for additional life.

See Wire Feed Drive Roll and Guide Tube Kits Sec - tion for roll changing instructions.

WIRE REEL SPINDLE

No routine maintenance required. Do not lubricate spindle.

CIRCUIT PROTECTION AND AUTOMATIC SHUTDOWN

CONTROL PC BOARD FUSE

On G1757-6 (or higher part no.) PC boards the 18 amp fuse was replaced with electronic protection for trigger circuit faults to electrode circuit.

On G1757-2 through -5 part no. PC boards, the 18 amp fuse interrupts the 500A lead to the trigger switch. On G1757- 1 PC boards a 5 amp fuse was used to interrupt the 667 lead. The LN-25™ will not operate if the fuse is blown.

AUTOMATIC PROTECTION SHUTDOWN

(See Automatic Protection Shutdown Section.)

ADJUSTING SPEED

SENSOR MODULE

The LN-25™ Speed Sensor Module is a three lead Hall Effect switch device encased in an externally threaded housing which is screwed into a mounting plate on the motor side of the wire drive gearbox.