F-16

TROUBLESHOOTING AND REPAIR

F-16

GAS SOLENOID VALVE AND CONTROL PC BOARD TEST

(FOR CODES ABOVE 10500 ONLY) (continued)

FIGURE F.7. – APPLIED VOLTAGE POLARITY.

ELECTRODE

CABLE

POLARITY

SWITCH

WORK SENSING LEAD

CONTROL PC BOARD SOLENOID CIRCUITRY

TEST

1.Apply at least 25 VDC but no more than 100 VDC to the LN-25™ from the electrode cable to the work sensing lead. Make sure the polarity switch is set to match the polarity of the electrode cable. For example, if the electrode cable is positive and the work sensing lead is negative, set the polarity switch to positive. See Figure F.7.

LN-25™