F-6

TROUBLESHOOTING AND REPAIR

 

 

F-6

 

 

 

 

 

 

 

 

 

Troubleshooting Guide – See Wiring Diagrams for location of specified

 

Observe Safety Guidelines

components. See Wiring Diagrams for troubleshooting of specific circuits.

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

 

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

 

 

 

The wire feed motor runs at a

1. Make sure the mode switch

 

1. Perform

the

Hall

Effect

constant speed with no control.

(S3) is in the CV mode.

 

Module Test.

 

 

NOTE:Loss of tach feedback may

2. Make sure the wire speed

 

2. Perform the Wire Drive Motor

 

result in MAX speed or a

control and the wire speed

 

Test.

 

 

 

 

motor voltage of approx.

range switch (S2)

are set

 

3. The control

board

may be

 

14VDC depending on the

correctly.

 

 

 

 

 

faulty. Replace.

 

 

Control Board being used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The gas solenoid valve will not

1. Make sure the LN-25™ is

 

1a.Perfor m the Solenoid PC

function.

equipped with a gas solenoid

 

Board and

Gas Solenoid

 

 

valve and properly connected.

 

Valve Test

 

 

 

 

2. Make sure the gas supply is

 

NOTE:Test is code specific.

 

 

adequate and the gas hoses

 

Codes above 10100 may

 

 

are not loose or kinked.

 

or may not have a

 

 

NOTE:Control Boards L12253-[ ]

 

Solenoid PC Board.

 

 

 

 

 

 

 

 

 

or higher do not use a Gas

 

2. If a K434-1 gas flow timer kit is

 

 

Solenoid PC Board.

 

installed in the unit, disconnect

 

 

 

 

 

and plug in the timer jumper

 

 

 

 

 

plug. If the gas solenoid

 

 

 

 

 

functions,

then replace the

 

 

 

 

 

K434-1 kit.

 

 

 

 

 

 

 

3. The contactor board or remote

 

 

 

 

 

control board (if used) may be

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

4. The control board may be

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

The contactor does not function.

1. Make certain the LN-25™ is

 

1. Perform the Contactor Test.

 

 

equipped with a contactor and

 

NOTE:Test

is

code

specific.

 

 

properly connected.

 

 

 

 

 

 

Codes above 10100 may

 

 

 

 

 

 

 

2. Check the connections to the

 

or may not have a

 

 

contactor PC board.

 

 

Contactor PC Board.

 

 

NOTE:Control Boards L12253-[ ]

 

2. The Contactor PC board or the

 

 

or higher do not

use a

 

Control Board may be faulty.

 

 

Contactor PC Board.

 

Replace.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.