How to use Table C.1.

 

Determine which Kit No. is to be used. Locate that Kit No. in the left hand vertical column.

Scan horizontally to determine which LN-25™ model is required and what additional kits may be required.

TABLE C.1

LN-25™ OPTION CHART

O = CANNOT BE USED WITH X = REQUIRED = REQUIRES ONE OF THESE

+ = INCLUDED WITH

 

 

 

 

 

 

 

 

SEE TEXT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KIT NO.

 

LN-25™ MODELS

 

 

 

 

 

LN-25™ KITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K428 LN-25™

K446 LN-25™

K449 LN-25™

K431-1

K432

K433

K443-1

K444

K444-1

K444-2

K460-1

K461

K624-1

K625

K626

K627

K430-1,2

Solenoid

X

+

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K431-1

Remote Output

O

 

X

X

O

O

O

O

O

 

O

 

 

 

 

Control Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K432

Remote

 

 

 

X

 

X

 

 

 

 

 

 

 

 

 

 

 

Control Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K433

115VAC

 

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

Power Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K434-1

Gas Flow

 

 

 

 

 

 

 

 

 

 

 

 

Timer Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K439

50 Ft.

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Ext. Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K443-1

Contactor Kit

 

 

+

O

 

 

 

 

 

 

O

 

O

 

 

 

 

K443-2

Contactor Kit

 

 

+

O

 

 

 

 

 

 

O

 

O

 

 

 

 

Codes 10500,10558

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K443-3

Contactor Kit

 

 

+

O

 

 

 

 

 

 

O

 

O

 

 

 

 

 

Codes 11144 & Above

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K444

Remote for Power

O

 

 

 

 

 

 

O

 

O

 

 

 

 

Source w/Terminal Strip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K444-1

Remote for Power

O

 

 

 

 

 

 

O

 

O

 

 

 

 

Source w/6 Pin Amphenol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K444-2

Remote for Power

O

 

 

 

 

 

 

O

 

O

 

 

 

 

Source w/14 Pin Amphenol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K-624-1

42VAC Remote

O

O

 

 

O

O

O

O

O

 

 

Output Control Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K625

500 Amp Cable /w Stud-

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

Type Output Terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K626

350 Amp Cable /w Stud-

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

Type Output Terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K627

400 Amp Cable /w Twist-

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

Mate™ Type Terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K460-1

Pulse Power™

O

O

 

 

O

O

O

O

 

X

O

 

 

 

 

Adapter Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K461

Pulse Power™

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

Control Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFETY NOTE: This wire feeder provides “COLD” electrode when gun trigger is released if equipped with K431-1, K432 or K433 remote output control system, or K443-2 internal contactor kit. This feature and the use of a DC Constant Voltage welder provide an added margin of safety when welding must be performed under electrically hazardous conditions such as: • Damp locations • While wearing wet clothing • On metal structures, or, • In cramped positions (sitting, kneeling or lying) if there is a high risk of unavoidable or accidental contact with the workpiece or ground.