TROUBLESHOOTING AND REPAIR

F-27

 

CONTACTOR & CONTACTOR PC BOARD TEST (continued)

 

 

FIGURE F.14 – CONTACTOR PC BOARDS

 

 

CODES 9812 AND BELOW

CODES BELOW 10500

 

Return

Return to Section TOC

to Section TOC

Return

Return to Master TOC

to Master TOC

S20963

J6

J7

CONTACTOR

COIL LEADS

J6

J7

#667

 

#621

J9

 

 

CONTACTOR

 

COIL LEADS

Return

Return to Section TOC

Return

Return to Master TOC

4. Apply 12 VDC to the contactor coil leads.

CAUTION

Do not leave the 12 VDC applied to the contactor coil for a prolonged period of time (15 seconds maximum). Damage to contactor may result.

5.If the contactor does not activate when the 12 VDC is applied, the contactor is faulty. Replace.

6.If the contactor activates when the 12 VDC is applied, check the resistance between the two large terminal studs with the contactor activated. The resistance should be very low (0 to 1 ohm).

7.If the resistance is “high” or “open” between the two large terminal studs when the contactor is activated, the contactor is faulty. Replace.

8.If the contactor activates and the resistance between the terminals is low when the 12 VDC is applied, the contactor is good.

NOTE: When the contactor is not activated, the resistance between the terminals should be very high (infinite). If the resistance is always low, the contacts are “stuck” and the contactor is faulty. Replace.