TROUBLESHOOTING AND REPAIR

F-15

GAS SOLENOID VALVE AND CONTROL PC BOARD TEST

(FOR CODES ABOVE 10500 ONLY) (continued)

FIGURE F.6. – SOLENOID LEADS.

SOLENOID LEADS

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

3.Locate and remove the two solenoid leads #690 and #691 from the solenoid valve. See Figure F.6.

4.Make sure the gas supply for the solenoid is hooked up, and then apply 12 VDC to the gas solenoid.

5.If the solenoid activates and allows gas flow, then the solenoid valve is good.

NOTE: There should not be any gas flow until the solenoid is activated.

6.If the solenoid does not activate and allow gas to flow, then the solenoid is faulty. Replace.

7.The normal solenoid resistance is approximately 20 to 27 ohms.