CONTACTOR REPLACEMENT (continued)

FIGURE F.25 - CONTACTOR REPLACEMENT.

Return to

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to

Return to Master TOC

Return to Master TOC

Return to Master TOC

11/16" BRASS

NUTS

IN-LINE

CONNECTORS

REEL STAND

ASSEMBLY

REPAIR PROCEDURE

1. Open the case door. Remove the wire reel by removing the retaining collar. See Figure F.5.

2. Remove the screws holding the control box cover in place and remove the control box cover. See Figure F.5.

3. Remove the baffle from in front of the contactor. See Figure F.25.

4. Remove the 5/16" screw holding the contactor in place.

5. Remove the two 11/16" brass nuts holding voltage sensing lead #67 and the welding cables to the contactor.

6. Disconnect the contactor coil leads by separating the two in-line connectors behind the reel stand assembly. For codes 9812 and below, remove the two contactor coil leads from the contactor PC board. See Figure F.25.

7. Cut or remove any cable ties or harness tape as necessary.

VOLTAGE SENSING

LEAD 67

WELDING CABLES

CONTACTOR

BAFFLE

5/16" SCREW

8. Carefully remove the contactor from the LN- 25™.

9. Install a new contactor in the LN-25™.

10. Connect the contactor coil lead in-line connectors behind the reel stand assembly. See Figure F.25. For codes 9812 and below, install the contactor coil leads onto the contactor PC board. See Figure F.19.

11. Install the welding cables and voltage sensing lead #67 to the contactor and secure with the two 11/16" brass nuts. See Figure F.25.

NOTE: Be sure brass nuts are tight. 11 ft-lb torque is recommended.

12. Install the 5/16" screw to secure the contactor in place.

13. Install the baffle in front of the contactor.

14. Install the control box cover and secure by installing the three screws. See Figure F.5.

15. Install the wire reel and retaining collar and close the case door. See Figure F.5.