ViewSonic PJ501 Troubleshooting, OSD Messages, Indicator Messages, Screen Message, Power, Lamp

Models: PJ551 PJ501

1 32
Download 32 pages 7.79 Kb
Page 24
Image 24
Troubleshooting

Troubleshooting

OSD Messages

The messages as described below may appear on the screen at POWER ON. Take the appropriate measures when such messages appear.

 

Table 10: OSD Messages

 

 

Screen Message

Meaning or Action Required

 

 

CHANGE THE LAMP. AFTER

The lamp will reach the end of its life in 300 hours. POWER is switched off

REPLACING LAMP, RESET THE LAMP

automatically when the lamp reaches the end of its life. prepare a new lamp

TIME. 1

for installation.

 

Always reset the lamp timer after replacing the lamp.

 

 

CHANGE THE LAMP. AFTER

The lamp will reach the end of its life in ** hours. POWER will be switched

REPLACING LAMP, RESET THE LAMP

OFF automatically in ** hours. Replace the lamp as shown in "Replacing

TIME. THE POWER WILL TURN OFF

the Lamp" on page 19.

AFTER ** HR. 1

Always reset the lamp timer after replacing the lamp.

CHANGE THE LAMP. AFTER

The lamp has reached the end of its life. POWER will be switched OFF in a

REPLACING LAMP, RESET THE LAMP

few minutes.

TIME. THE POWER WILL TURN OFF

Switch POWER OFF immediately and replace the lamp as shown in

AFTER 0 HR.

"Replacing the Lamp" on page 19.

 

 

Always reset the lamp timer after replacing the lamp.

 

 

NO INPUT IS DETECTED

No input signal found.

ON ***

Check signal input connections and signal sources.

 

 

SYNC IS OUT OF RANGE ON ***

The horizontal or vertical frequency of the input signal is not within the

 

specified range.

 

Check the specifications of the equipment and the signal source.

 

 

CHECK THE AIR FLOW

The internal temperature has risen.

 

Switch POWER OFF, and wait 20 minutes until the equipment cools.

 

Check the following and switch POWER ON again.

 

• Are the ventilation openings blocked?

 

• Is the air filter dirty?

 

• Is the ambient temperature in excess of 95°F (35°C)?

 

 

1This message is cleared automatically after approximately three minutes, and appears every time POWER is switched ON.

Indicator Messages

The POWER indicator, LAMP indicator, and TEMP indicator are either lit, unlit or blinking as explained in the table below.

 

 

 

Table 11: Indicator Messages

 

 

 

 

 

POWER

LAMP

TEMP

 

Meaning or Action Required

indicator

indicator

indicator

 

 

 

 

 

 

Lights orange

Turns off

Turns off

 

The Standby mode has been set.

 

 

 

 

 

Blinks green

Turns off

Turns off

 

Warming up. Please wait.

 

 

 

 

 

Lights green

Turns off

Turns off

 

ON. Normal operation possible.

 

 

 

 

 

Blinks orange

Turns off

Turns off

 

Cooling. Please wait.

 

 

 

 

 

Blinks red

-

-

 

Cooling. Please wait.

 

 

 

 

The error is found. Take the appropriate measures when the POWER

 

 

 

 

indicator ceases blinking.

 

 

 

 

 

21 ViewSonic PJ501/PJ551

Page 24
Image 24
ViewSonic PJ501 Troubleshooting, OSD Messages, Indicator Messages, Screen Message, Meaning or Action Required, Power, Lamp