Lincoln Electric SVM114-C service manual Figure F.2 Solenoid Leads

Models: SVM114-C

1 111
Download 111 pages 23.31 Kb
Page 47
Image 47

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-9

TROUBLESHOOTING AND REPAIR

F-9

GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST

(continued)

FIGURE F.2 – SOLENOID LEADS.

SOLENOID LEADS

SOLENOID LEADS

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

3.Locate and remove the two solenoid leads from the solenoid valve (For codes 9812 and below, remove the two leads from the Solenoid PC Board). See Figure F.2.

4.Make sure the gas supply for the solenoid is hooked up, and then apply 12 VDC to the gas solenoid.

5.If the solenoid activates and allows gas flow, then the solenoid valve is good.

NOTE: There should not be any gas flow until the solenoid is activated.

6.If the solenoid does not activate and allow gas to flow, then the solenoid is faulty. Replace.

7.The normal solenoid resistance is approximately 20 to 27 ohms.

LN-25™

Page 47
Image 47
Lincoln Electric SVM114-C service manual Figure F.2 Solenoid Leads