THEORY OF OPERATION

E-5

PROTECTIVE DEVICES AND

CIRCUITS

OVERVOLTAGE SHUTDOWN

If the power source open circuit voltage exceeds about 110-120 volts, the LN-25™ will not operate until the power source voltage drops below about 102-112 volts.

MOTOR OVERLOAD SHUTDOWN

If excessive motor overload occurs (due to prolonged excessive feeding force, jammed drive rolls or shorted motor leads) the LN-25™ will shut down within a few seconds after the overload occurs. The shutdown will reset automatically when the gun trigger is released, but will reoccur if the overload situation is not remedied

CONTROL PC BOARD FUSES

On G1757-2 thru -5 part no. PC boards, the 1/8 amp fuse interrupts the 500A lead to the trigger switch. On G1757-1 PC boards, a 5 amp fuse was used to interrupt the 667 lead. The LN-25™ will not operate if either fuse is blown.

On G1757-6 (or higher) part no. PC boards, the 1/8 amp fuse was replaced with electronic protection for trigger circuit faults to electrode circuit.