3.SETUP

AC Power The Minisphere™ 3.1 has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz.

To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.

Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0~100% switch.

Fuse

Replacement

Disconnect the product from power before replacing the fuse.

1.Disconnect the product from power.

2.Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.

3.Pry the fuse holder out of the housing.

4.Remove the blown fuse from the holder.

5.Replace with a fuse of the exact same type and rating.

6.Insert the fuse holder back in place and reconnect power.

Installed fuse

(held by plastic clip)

Spare fuse holder (inside safety cap)

Safety cap

A spare fuse is not included; however, the safety cap has room for a spare.