Chauvet 560 user manual Fan Wait System Default Edit Custom, Operation, Go to MENU SPECIAL FANWAIT

Models: 560

1 31
Download 31 pages 60.93 Kb
Page 19
Image 19
Fan Wait

Operation

Fan Wait

System Default

Edit Custom

Stop the fan during a blackout.

1.Go to MENU > SPECIAL > FAN_WAIT.

2.Select ON or OFF.

Default all product parameters to their default values.

1.Go to MENU > EXTRA.

2.Press <ENTER> (PASSWORD) will show on the display.

3.Press <ENTER> (**** will show on the display).

4.Enter the password, as explained in Keylock.

5.Use <UP> to select DEFAULT.

6.Press <ENTER> (NO will show on the display).

7.Select YES and press <ENTER> to default the product or press <MENU> to exit.

Program up to 255 steps in a single custom program.

1.Go to MENU > EDIT.

2.Press <ENTER> to go to STEP.

3.Press <ENTER> to select a value. The current value (001~255) will show on the LCD.

4.Press <UP> or <DOWN> to select a new value.

5.Press <ENTER> to accept the value.

6.Press <ENTER> to go to PAN.

7.Repeat steps “1” through “6” for TILT, SPEED, COLOR, GOBO1, GOBO2, GOBO2ROT, PRISM, PRISMT, IRIS, FOCUS, DIMMER, STROBE, and TIME.

8.Press <ENTER> to go to USE.

9.Select YES to save the settings for this step or NO to delete them.

10.Repeat steps “3” to “8” for the other steps.

The product will execute all the steps in the CUSTOM program and stop.

To make the product start over, add a last step whose duration is 0 seconds. Example:

Step 1:

Time = 5

Use = Yes

 

Step 2:

Time = 4

Use = Yes

 

Step 3:

Time = 6

Use = Yes

 

Step 4:

Time = 0

Use = Yes

(This step creates a loop)

Step 5:

Time = 0

Use = No

 

 

 

 

(Unused steps)

Step 255

Time = 0

Use = No

 

Q-Spot™ 560-LED User Manual Rev. 06