5.APPENDIX

5.APPENDIX

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA- 485 standard, no more than 32 fixtures should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.

Maximum recommended serial data link distance: 500 m (1640 ft)

Maximum recommended number of fixtures on a serial data link: 32

Tto use this fixture in a DMX or master/slave operation, you must daisy chain, using DMX cables to link from one fixture to another.

Additional signal

link out

Setting up a DMX Serial Data Link

Universal DMX Controller

1. Connect the (male) 3-pin connector side of

 

the DMX cable to the output (female) 3-pin

 

connector of the controller.

 

2. Connect the end of the cable coming from

 

the controller which will have a (female)

 

3-pin connector to the input connector of

 

the next fixture consisting of a (male) 3-pin

 

connector.

This drawing

 

3. Then, proceed to connect from the output

provides a general

illustration of the

as stated above to the input of the following

DMX input/output

fixture and so on.

panel of a lighting

 

fixture.

Continue the link