Operating Instructions
the start address. Determining which switches to toggle ON given a specific start address can be accomplished in the following manner. By subtracting the largest switch value possible from the selected start address which does not cause a negative number.
EXAMPLE STARTING
ADDRESS
Address 10
Pin # 4 | = 8 |
Pin # 2 | = 2 |
Total | = 10 |
THE CHANNEL ADDRESSES WERE SELECTED AT RANDOM. IT IS RECOMMENDED TO SEQUENCE YOUR FIXTURES FOLLOWING A NUMERICAL ORDER.
DMX Values
Address 24
Pin # 5 | = 16 |
Pin # 4 | = 8 |
Total | = 24 |
DMX Values
Resolving address using simple math.
Address 233
233 – (128) = 105, Turn ON Dip # 8
41 (32) = 9, Turn ON Dip # 6 | |
9 | – (8) = 1, Turn ON Dip # 4 |
1 | – (1) = 0, Turn ON Dip # 1 |
You will most likely use the first available number which maybe number 1. This number was selected for example purposes.
DIP SWITCH
1
2
3
4
5
6
7
8
9
10
(DMX VALUE)
1
2
4
8
16
32
64
128
256
10 | Revision: 5/17/2005 10:49 PM |