Chauvet FX 2.0, RGX 2.0 user manual Appendix, General Troubleshooting

Models: FX 2.0 RGX 2.0

1 16
Download 16 pages 3.09 Kb
Page 13
Image 13

5. APPENDIX

General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

 

 Excessive circuit load

 Check total load placed on the

Breaker/Fuse

electrical circuit.

 

keeps blowing

 Short circuit along the power

 Check for a short in the electrical

 

wires

wiring (internal and/or external).

Device does not

 No power

 Check for power on Mains.

power up

 Loose power cord

 Check power cord

 

 Wrong DMX addressing

 Check Control Panel and unit

 

addressing

 

 

Product is not

 Damaged DMX cables

 Check DMX cables

 Wrong polarity settings on the

 Check polarity switch settings on

responding to

controller

the controller

DMX

 Loose DMX cables

 Check cable connections

 

 

 Faulty DMX interface

 Replace DMX input

 

 Faulty Main PCB

 Replace Main PCB

 

 Non DMX cables

 Use only DMX compatible cables

 

 Bouncing signals

 Install terminator as suggested.

 

 Long cable / Low level signal

 Install amplifier right after product

Loss of signal

with strong signal.

 

 Too many products

 Install an optically coupled DMX

 

 

splitter after unit #32.

 

 

 

 Interference from AC wires

 Keep DMX cables separated from

 

power cables or black lights.

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET®

Technical Support.