1.If the alarm sounds, this means that the input voltage is at or below 11 V. The bat- tery needs recharging. You should stop using the Power Inverter and recharge the battery. If this is not done, the Inverter will shut off automatically at 10.5V.

2.If you are unsure if the inverter will have the proper amount of current to run your devices, add up the total of the continuous wattage for the items. If this figure is under 80 then the Inverter will be able to run the items at the same time.

3.If your audio system buzzes while using this inverter, it is because some sound systems can not filter out the modified sine wave produced by the inverter. Use a sound system that incorporates a higher quality power supply.

4.If the low battery alarm is on all the time, try these corrective measures: Recharge battery if in poor condition. Next, check the connection into the cigarette lighter socket. You may need to clean the connectors.

5.If you are getting a low output voltage, try reducing the load to minimize watts. You may have overloaded the inverter. Reduce the number of watts you are powering.

Also, keep input voltage above 11 volts to maintain a constant flow of power.

6.If you are not getting any power output, your devices may draw too much power to operate them. The inverter may be in thermal shutdown. Remove it from the ciga- rette lighter socket, let it cool down, then re-insert it, making sure there is adequate ventilation around the unit.