SKU 90236 For technical questions, please call 1-800-444-3353. Page 14
To Start The Generator:
1. Turn the Fuel Valve (31) to its vertical
“OPEN” position.
(See Figure E.)
2. Move the Engine’s Fuel Choke all the
way to the right to its “START” posi-
tion. (See Figure E.)
3. Turn the Engine’s “ON/OFF” Switch
(46) to its “ON” position
(See Figure F.)
4. Grasp the Handle of the Engine’s
Starter Pulley and rapidly pull the
Starter Pulley to start the Engine.
NOTE: It may take more than one pull
on the Starter Pulley to start the En-
gine.
5. Allow the Engine to run for several
seconds, then move the Engine’s Fuel
Choke all the way to the left to its
“RUN” position. (See Figure E.)
NOTE: DO NOT ATTEMPT TO ADJUST
THE ENGINE’S THROTTLE! This
engine uses a governor device to
automatically control the engine’s
speed. If the throttle is adjusted, it
may result in decreased efficiency
and/or damage to the unit. FIGURE F
ON/OFF
Switch
FUEL VALVE (31)
Hidden from view
CHOKE
FIGURE E
FIGURE G
120V DUAL OUTLET
(43)
OVERLOAD BREAKERS
(42)
120/240 V
TWISTLOCK OUTLET
(44)
GROUNDING POINT
REV 06/04; 11/04