Chicago Electric 95519 manual Specifications, General Safety Rules, Work Area, Electrical Safety

Models: 95519

1 9
Download 9 pages 60.44 Kb
Page 2
Image 2

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

 

 

 

 

Continuous Output Power

 

100 Watts

 

 

Peak Power

 

200 Watts

 

 

Input Voltage

 

13.8 Volts DC

 

 

Output Voltage

 

115 Volts AC @ 60 Hz

 

 

Automatic Shutdown

 

At 10.2 Volts DC

 

 

AC Receptacle

 

One 3-Prong, Grounding Outlet

 

 

USB Port Output

 

5 Volt/250 mA DC (500 mA Maximum)

 

 

Maximum Efficiency

 

Approximately 80% with Full Load

 

 

Power Connector Type

 

16 AWG x 2C x 24” Long Wire/Lighter Plug with F10A/250V Fuse

 

 

Power Switch Type

 

Clear Push-Button with 3-Way LED:

 

 

 

 

Green LED Indicates 12 Volt DC Power to Unit

 

 

 

 

Green LED Indicates AC Power Output is Active

 

 

 

 

Red LED Indicates Overheating, Electrical Problem

 

 

Thermal Shutdown

 

<149° F

 

 

Accessories

 

Carrying Case

 

 

Dimensions

 

4” W x 2-9/16”L x 7/8” T

 

 

Unit Weight

 

0.4 Pound

 

 

 

 

 

 

 

 

 

SAVE THIS MANUAL

You will need this manual for the safety warnings and precautions, assembly, oper- ating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep this manual and invoice in a safe and dry place for future reference.

GENERAL SAFETY RULES

WARNING!

READ AND UNDERSTAND ALL INSTRUCTIONS

Failure to follow all instructions listed below may result in

electric shock, fire, and/or serious injury.

SAVE THESE INSTRUCTIONS

WORK AREA

1.Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.

2.Do not operate power equipment in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power equipment creates sparks which may ignite the dust or fumes.

ELECTRICAL SAFETY

1.Never remove the grounding prong of a power tool or appliance or modify the plug in any way. Do not use any adapter plugs with this product. If the tool or

SKU 95519

For technical questions, please call 1-800-444-3353