3.Thermal shutdown protection: The Inverter will automatically shut down when the unit exceeds 149° Fahrenheit.
4.Overload & short circuit protection: The Inverter will automatically shut down when a short circuit occurs.
5.AC ground leakage: The Inverter will automatically shut down when current leak- age exceeds safety level.
6.NOTE: The LED Light on the Inverter will illuminate RED to indicate an input voltage problem or alternately blink RED and BLUE to indicate one of the other problems listed above before automatic shut down occurs.
If the Inverter shuts down, turn its Power Switch to “OFF”. Remove the load. Wait several minutes. Then, turn the unit back on.
TOOL/APPLIANCE POWER CONSUMPTION
The Table below gives approximate general use wattage. Always verify the tool/ appliance wattage before using the Inverter.
TOOL/APPLIANCE | WATTAGE |
Buffer | 77 Watts |
Camcorder Charger | 99 Watts |
Drill Charger | 8 Watts |
Glue Gun | 20 Watts |
13” Color Television | 72 Watts |
VCR | 40 Watts |
CD Changer | 60 Watts |
Laptop Computer | 80 Watts |
SKU 95519 | For technical questions, please call | PAGE |