RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

AMPERES

(at full load)

0 – 2.0

2.1– 3.4

3.5– 5.0

5.1– 7.0

7.1– 12.0

12.1– 16.0

16.1– 20.0

TABLE A

EXTENSION CORD

LENGTH

25’

50’

75’

100’

150’

18

18

18

18

16

18

18

18

16

14

18

18

16

14

12

18

16

14

12

12

18

14

12

10

-

14

12

10

-

-

12

10

-

-

-

 

 

 

 

 

*Based on limiting the line voltage drop to five volts at

150% of the rated amperes.