MAINTENANCE

WARNING!

Disposing of Nickel-Cadmium Battery Packs

WARNING!

To reduce the risk of injury, always unplug the charger and remove the battery pack from the charger or tool before performing any maintenance. Never disassemble the tool, battery pack or charger. Contact

a MILWAUKEE service facility for ALL repairs.

Keep your tool, battery pack and charger in good repair by adopting a regular main- tenance program. After six months to one year, depending on use, return the tool, battery pack and charger to a MILWAUKEE service facility for:

Use a Chicago Pneumatic battery pack only until it no longer performs with the power and torque needed for your appli- cation.

Store your battery pack in a cool, dry place. Do not store it where the temperature may exceed 120°F (50°C) such as a vehicle or metal building during the summer. High tem- peratures will overheat the battery pack, reducing battery life. If it is stored for sev- eral months, the battery pack will gradu- ally lose its charge. One to three cycles of charging and discharging through normal use will restore the capacity of the battery pack. During the life of the battery pack the operating time between charges becomes shorter. If the operating time becomes ex- tremely short after a proper charge, the usable life of the battery pack has been

To reduce the risk of explosion, never burn a battery pack even if it is damaged, dead or com- pletely discharged.

RBRC Battery Recycling Seals

The RBRC™ Battery Recycling Seals (see "Symbology") on your tool battery packs in- dicate that MILWAUKEE has arranged for the recycling of that battery pack with the Rechargeable Battery Recycling Corporation (RBRC). At the end of your battery pack's useful life, return the battery pack to a MILWAUKEE Branch Office/Service Center or the participating retailer nearest you. For more information, visit the RBRC web site at www.rbrc.org.

Nickel-Cadmium battery packs are recy- clable. Under various state and local laws, it be be illegal to dispose of this batter into the municipal waste stream. Dispose of your battery pack according to federal, state and local regulations.

Repairs

For repairs, return the tool, battery pack and charger to the nearest service center listed on the back cover of this operator's manual.

Battery Pack Warranty

Battery packs for cordless tools are warranted for one year from the date of purchase.

Lubrication

Mechanical inspection and cleaning (gears, spindles, bearings, housing, etc.)

Electrical inspection (battery pack, charger, motor)

Testing to assure proper mechanical and electrical operation

Maintaining Tool

If the tool does not start or operate at full power with a fully charged battery pack, clean the contacts on the battery pack. If the tool still does not work properly, return the tool, charger and battery pack, to a MILWAUKEE service facility for repairs.

Maintaining Battery Pack

Chicago Pneumatic battery packs will op- erate for many years and/or hundreds of cycles when they are maintained and used according to these instructions.

A battery pack that is stored for six months without being used will discharge itself. Batteries discharge at a rate of about 1% per day. Charge the battery every six months even if it is unused to maximize battery life. Do not tape the trigger in the “ON” position and leave the tool unattended as this may discharge the battery to a point where it will no longer be able to recharge.

reached and it should be replaced.

WARNING!

To reduce the risk of personal injury and damage, never im- merse your tool, battery pack or charger in liquid or allow a liquid to flow inside them.

Cleaning

Clean dust and debris from charger and tool vents. Keep tool handles clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean the tool, battery pack and charger since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lac- quer thinner, paint thinner, clhlorinated clean- ing solvents, ammonia and household deter- gents containing ammonia. Never use flam- mable or combustible solvents around tools.

WARRANTY

Chicago Pneumatic Tool Company Limited Warranty and Service Policy

Products of the Chicago Pneumatic Tool Company (“CP”) are warranted to be free from defects in material and workmanship for one year from the date of purchase. This warranty applies only to Products purchased new from CP or its authorized dealers. Of course this warranty does not apply to Products which have been abused, modified, or repaired by someone other than CP or its Authorized Service Representatives.

If a CP Product proves defective in material or workmanship within one year after purchase, return it to any Authorized Service Center* transportation prepaid, enclosing your name and address, adequate proof of date of purchase and a short description of the defect. CP (or its affiliate) will, at its option, repair or replace defective Products free of charge. Repairs or replacements are warranted as described above for the remainder of the original warranty period. CP’s sole liability and your exclusive remedy under this Warranty is limited to repair or replacement of the defective Product.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRAN- TIES, OR CONDITIONS, WRITTEN OR ORAL, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ALL WARRANTIES OR CONDITIONS, OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ALLOF WHICH ARE HEREBY DISCLAIMED. THERE SHALL BE NO LIABILITY FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, OR ANY OTHER DAMAGES, COSTS OR EXPENSES, EXCEPTING ONLY THE COST OR EXPENSE OF REPLACEMENT OR REPAIR.

Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts is not covered by Warranty. This warranty gives specific legal rights. Consumers may have other rights under state or federal law.

Chicago Pneumatic Tool Company

1800 Overview Drive

Rock Hill, South Carolina 29730-7463

*CP Products described in this manual may be sent to any MILWAUKEE ELECTRIC TOOL CORPORATION Branch Office/Service Center or Authorized MILWAUKEE Ser- vice Station for repair. See back page for information on how to locate a facility nearest you.