track, or is the motor box bent, causing it to become uncoupled from the track?

Power Loss - The Status Light will be on solid red. ---- There

has been a power loss (due to an electrical storm, etc.). When next activated the doors will move at a slow speed to their full closed position. If the doors are already closed they will not move. The Status Light will return to solid green and the doors are ready for normal activation.

Optional Control Input Connections

Control Input- 8 position RJ 45 modular phone jack

Discrete control for use with 3rd party control.

Position 8- Open

Position 7- Stop

IR Receiver “Eye” input for Eubank, Inc. supplied external IR reciever only.

Position 6 - V out

Position 5 - Vcc, 5v

Radio Power for external RF receiver only.

Position 4 - 24 VDC

Sequence control for use with 3rd party control.

Position 3 - Sequence- Open, Stop, Close, Stop

Position 2 - Common

Discrete control for use with 3rd party control.

Position 1 - Close

Control Input on Front of Motor Box

Control Input

Figure 14

NOTE: Making a momentary dry contact closure between the common and the open, closed, stop, or sequence will activate the system in that mode.

Control Input on Front of Motor Box

Figure 15

10