![I N S T A L L A T I O N I N S T R U C T I O N S](/images/new-backgrounds/42994/429941x1.webp)
I N S T A L L A T I O N I N S T R U C T I O N S
STRUCTURAL CEILING PLATE WITH FLEX JOINTS
CMA-345![STRUCTURAL CEILING PLATE WITH FLEX JOINTS](/images/new-backgrounds/42994/429941xi2.webp)
![STRUCTURAL CEILING PLATE WITH FLEX JOINTS](/images/new-backgrounds/42994/429941xi2.webp)
The
WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY! When mounting Chief Manufacturing accessories, the structural system and mounting method MUST be capable of supporting 5 times the combined weight of the total installation.
The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg).
Unpack and check contents:
(1) Structural Ceiling Plate
(1) 5/32” Allen Wrench
INSTALLATION INSTRUCTIONS
1.Secure ceiling plate to structural member. (SEE WARNING ABOVE) Bolt hole spacing is shown on Figure 1.
2.Thread your standard NPT 1 1/2” pipe or extension column into ceiling plate, tighten securely.
3. . Install and securely tighten the 5/16 – 18 socket set screw.
7.25
3.36
6.50
3.25
3.13
7.25
6.25
1 1/2" NPT
6X %%c.38
Figure 1. CMA-345 Dimensions