Chief Manufacturing PAC502 Installation Instructions, Grounding Lug Locations

Models: PAC502

1 8
Download 8 pages 23.08 Kb
Page 6
Image 6
Grounding Lug Locations

PAC502

Installation Instructions

4.Center PAC502 (A) in opening and insert into opening. Align front of box with front face of wall. (See Figure 3)

(A)

Figure 3

WARNING: ELECTRICAL SHOCK HAZARD! CUTTING OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind

mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.

5.Drill four 3/16" diameter pilot holes in studs at side mounting holes. (See Figure 4)

6.Attach the PAC502 (A) to side studs using four M7 x 50mm Allen head connector screws (D) and mounting spacers (B) using an M4 Allen head drill bit (F). (See Figure 4)

 

6

(D) x 4

 

 

(B) x 4

5

xx4

 

Figure 4

NOTE: The PAC502 has 1/2" total clearance between the two studs. The spacers allow side to side adjustment.

7.Drill eight 3/16" diameter pilot holes in horizontal framing at top and bottom mounting holes. (See Figure 5)

8.Attach the PAC502 (A) to horizontal framing using eight

M7 x 40mm Allen head connector screws (C) using an M4 Allen head drill bit (F). (See Figure 5)

 

7

x 8

8

(C) x 8

 

Figure 5

DANGER: IMPROPER WIRING CAN LEAD TO DEATH OR SEVERE PERSONAL INJURY! Grounding must be installed by qualified personnel using a UL Recognized No. 12AWG Green and Yellow grounding wire connected to grounding lug on mount.

Grounding Lug Locations

Figure 6

6

Page 6
Image 6
Chief Manufacturing PAC502 installation instructions Installation Instructions, Grounding Lug Locations