Chief Manufacturing PACPC1 Installation, Attaching to Drywall, Attaching to Wood Stud

Models: PACPC1

1 8
Download 8 pages 49.17 Kb
Page 5
Image 5

Installation Instructions

PACPC1

INSTALLATION

 

Attaching to Drywall

(D)

1.

Attach bracket (D) to drywall using two #6 x 1" drywall

 

 

 

screws (L). (See Figure 1)

(C)

NOTE: Do NOT overtighten drywall screws.

 

2.

Proceed to Installing Conditioner.

 

 

 

(D)

 

 

 

 

(K) x 2

 

 

 

Conditioner to be Attached Horizontally

 

 

(L) x 2

 

 

 

Figure 1

 

Attaching to Wood Stud

 

1. Drill two 0.08" pilot holes into wood stud. (See Figure 2)

 

2.

 

Attach bracket (D) to wall using two #6 x 1" drywall

 

 

 

screws (L).

 

3.

 

Proceed to Installing Conditioner.

Conditioner to be Attached Vertically

 

 

Wood

 

 

 

Stud

Figure 3

 

 

 

 

 

1

2. Attach pole clamp (B) around the pole to the pole mount

 

 

 

bracket using two 1/4-20 x 1-1/4" buttonhead security

 

 

 

screws (H), four 1/4" washers (N), and two spacers (M).

 

 

(D)

(See Figure 4)

 

 

 

 

2

(L) x 2

(B)

 

 

 

 

 

Wall

 

 

 

 

(N) x 4

 

 

 

(M) x 2

 

 

Figure 2

 

Attaching to 1-1/2" NPT Pole

 

1.

 

Attach bracket (D) to pole mount bracket (C) using two

 

 

 

1/4-20 x 1/4" buttonhead screws (K). (See Figure 3)

1-1/2" NPT Pole

NOTE: The bracket can be installed for either horizontal or

(H) x 2

 

 

vertical attachment of the conditioner. (See Figure 3)

(Horizontal Attachment Shown)

Figure 4

5

Page 5
Image 5
Chief Manufacturing PACPC1 Installation, Attaching to Drywall, Attaching to Wood Stud, Attaching to 1-1/2 NPT Pole