Diagram 1

3 Phase Voltage 3 Phase Voltage 3 Phase Voltage
Boiler 208 240 480 Boiler 208 240 480 Boiler 208 240 480
WIRING
TYPICAL WIRING DIAGRAMS
WARNING: Hazard of Electric Shock. Boiler must be
suitably grounded according to N.E.C. standard.
1. Be sure to use the proper wire. Electric wiring to boiler should be
in accordance with National Electrical Code or local wiring code
following wiring diagram supplied. (See recommendations on
safety switches and fusing.)
2. The unit is completely wired and pre-tested before shipment. No
internal wiring is required.
If a separate control circuit is used, the control circuit should be
connected to the control terminal block, inside access door (not
required with transformer).
3. Safety Switches — WARNING: Purchaser should use a
safety switch employing circuit breakers or fuses
between his main power source and the boiler.
4. Because of their water lines, boilers are susceptible to lightning
damage. Industrial type lightning protectors should be installed per
manufacturer’s recommendations at your service entrance. Check
your contractor or electrical dealer for recommended type for your
system.
5. Be sure all electrical connections are sufficiently tightened.
6. WARNING: Substitution of components or modifica-
tion of wiring system voids the warranty and may
lead to dangerous operating conditions.
7. SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY-
ING THEIR OWN CONDENSATE OR PUMP SYSTEMS.
A. Check the voltage of the motor before making the wiring con-
nection. Some Chromalox boilers are supplied with dual volt-
age systems. The motor should always match the voltage of the
control circuit.
B. The motor circuit should be wired into the pump control as
shown in wiring diagram (float type pump control). If boiler is
equipped with solid state pump control, refer to wiring diagram
and use terminals 5 and 2.
Use Applicable wiring diagrams based on model number and power voltage.
CES-6 1 1 1 CES-30 2 2 3 CES-100 8 8 9
CES-9 1 1 1 CES-36 2 2 3 CES-135 10 11
CES-12 1 1 1 CES-48 4 4 5 CES-160 12 13
CES-18 1 1 1 CES-60 6 6 7 CES-180 10 11
CES-24 2 2 3 CES-72 6 6 7 Export 14
2PS
BR
Heater
Contactors
Feed Water
Boiler On
3
GND
B
FU6
B1PB
Off
1
GND
1
GND
1 HTR C1 FU1
FU2
FU3
FU5
FU4
H1 H2
X1 X3
L3
1L1
1L3
1L2
L2L1
X2 X4
Optional Transformer
1
1
C1
2
2
C4
C3
C2
R
1LT
Y
On
IFS
O1PS OO
W
Feed Water
Electrical
Connection
21
1TB
123
3
GND
1
GND 2
GND
1
HTR
FU6
FU
1PB
Cabinet Exterior Left Side Cabinet Exterior Right Side
Panel Layout
Wire Color Code
B = Black
BR = Brown
R = Red
O = Orange
Y = Yellow
G = Green
BL = Blue
W = White
* Boilers under 40 Amps total (not fused)
4