Chromalox®
Installation Instructions
and
RENEWAL PARTS IDENTIFICATIONDIVISION 4 |
| SECTION HF | |
SALES | (Supersedes |
| |
REFERENCE | |||
|
|
|
Portable Unit Blower Air Heater — Type HF
Specifications - Table A
Model |
| Model | Volts | Watts | Amps | Wiring | Plug |
Number |
| Fig. No. | Fig. No. | ||||
|
|
|
|
| |||
HF203G AC | C | 120V1P | 1,900 | 15.8 | 6 | 3 | |
HF203G AC | C | 240V1P | 2,000 | 8.3 | 6 | 4 | |
HF303H AC* | C | 120V1P | 3,000 | 25.0 | 7 | — | |
HF303G AC | C | 240V1P | 3,000 | 12.5 | 7 | 3 | |
HF403G AC | C | 240V1P | 4,000 | 16.7 | 7 | 5 | |
HF203EG DC | E | 120V1P | 1,900 | 15.8 | 9 | 3 | |
HF203DG DC | E | 240V1P | 2,000 | 8.3 | 8 | 4 | |
HF303E | DC* | E | 120V1P | 3,000 | 25.0 | 12 | — |
HF303DG DC | E | 240V1P | 3,000 | 12.5 | 11 | 4 | |
HF403E | DC** | E | 240V1P | 4,000 | 16.7 | 11 | — |
|
|
|
|
|
|
|
|
*Cord Only, no plug.
**Without Cord and plug.
1” |
|
| |
| |||
|
| ||
|
| ||
|
|
|
|
8”
Figure 1
On/Off |
|
Switch | Figure 2A |
Figure 2 |
GENERAL
Hazard of Fire or Discoloration of Temperature Sensitive Fabrics. Keep combustible material and such fabrics away from heater. Do not operate heater where flammable vapors, gases or liquids are present. Heaters should not be operated in room temperatures above 80˚F.
Hazard of Electric Shock. Any installation involving electric heaters must be effectively grounded in accordance with the National Electrical Code. Use the required polarized wall receptacle that mates with the appropriate plug, referenced in Table A, shown in Figures 3, 4 or 5 (see Page 2).
To avoid personal injury read “IMPORTANT INSTRUCTIONS” on page 3 before installation or operation of heater.
© 2010 Chromalox®, Inc.