WIRING DIAGRAMS
|
|
| Field Installed |
|
|
|
|
|
|
|
| To Element Wiring |
| ||||
|
|
| Factory Wiring |
|
| |||
|
|
| Optional |
|
|
|
| |
|
|
|
|
|
| Optional |
| |
|
|
|
| Thermostat |
|
| Fan Relay | Motor |
1 Phase 2 Or 3 Elem |
|
| ||||||
|
|
|
| Field Installed |
|
| Field | 1Ø Or 3Ø |
|
|
|
| C1 | Cutout |
| Installed |
|
|
|
|
|
|
|
|
| |
|
|
|
| C2 |
|
|
|
|
|
|
| 1 | 2 |
| T1 T2 T3 |
| T1 T2 T3 |
T1 | T2 | T3 | 3 | C3 |
| C1 |
| C3 |
C1 |
|
| 7 |
|
|
|
| |
|
|
| 9 | 8 |
|
|
|
|
L1 | L3 | 10 | 11 |
|
|
|
| |
12 |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
| Optional |
|
|
|
|
3 Phase Delta | Summer Fan Switch |
|
|
| ||||
|
|
|
| |||||
|
|
|
|
|
| 3Ø Wiring Only | ||
|
|
|
| Installed |
| L1 L2 L3 | ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Power |
|
|
|
| Motor |
|
|
| 60 HZ |
T1 T2 T3 |
|
| 1Ø Or 3Ø |
|
|
|
| |
|
|
|
|
|
|
| ||
C1 |
|
| T1 T2 T3 |
|
| Optional Disconnect Switch | ||
|
|
|
|
| ||||
L1L2L3 |
| C1 |
|
|
| |||
|
|
|
| |||||
| Standard Motor Connection |
|
| |||||
|
|
|
| |||||
|
|
|
|
|
|
Field Installed
Factory Wiring
Optional
Thermostat
X1 X2
H1H2
Transformer Color Code Index
PRI. | PRI. XFMR | 120V SEC. | 24V SEC. | ||||
VOLT. | LEAD | CLRS. | LEAD CLRS. | LEAD | CLRS. | ||
| H1 |
| H2 | X1 | X2 | X1 | X2 |
208 | BLK |
| RED | BLK | WHT | YEL | BLU |
240 | BLK |
| ORG | BLK | WHT | YEL | BLU |
480 | BLK | BLK/RED | BLK | WHT | YEL | BLU |
| Elements |
| Elements | ||
|
|
| Motor |
| |
|
|
| 3o |
| |
| Stage 1 |
| Stage 2 | ||
|
|
| Fuses |
| |
|
|
|
| ||
| C1 | T1 T2 T3 |
| T1 T2 T3 | |
Cutouts | Contactor (Typ.) | C2 | |||
|
|
|
| ||
XFMR |
|
|
|
| |
|
|
| Fuses |
| |
|
| AL2 AL3 | (When Req'd) | BL3 | |
|
| AL1 |
| BL1 BL2 | |
Optional Disconnect | L3 | 3 Phase, | |||
Switch | L2 | 60 HZ Power | |||
L1 | |||||
Field Installed |
| ||||
|
| ||||
|
|
Figure I
Figure J
To Elements | To Elements |
|
| Elements |
| Elements |
|
| |||
Stage 1 | Motor | Stage 2 |
| Optional |
|
|
| Motor | |||
|
|
|
|
|
|
|
| ||||
|
| 3Ø |
|
|
| Thermostat |
|
| 3Ø |
| |
|
|
|
|
|
| Stage 1 |
| Stage 2 |
| Fuses | |
|
|
|
|
|
| Field Installed |
|
|
| ||
T1 T2 | T3 |
| T1 T2 | T3 |
| Cutouts |
|
| 1 | 2 | |
C1 |
|
| C2 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| 3 |
| ||
|
|
|
|
|
|
| T1 T2 T3 |
| T1 T2 T3 |
| |
|
|
|
|
|
|
|
| 7 |
| ||
|
|
|
|
|
|
| C1 | Contactor C2 |
| ||
Standard Motor Connection |
|
|
| (Typ.) |
| 9 | 8 | ||||
X1 | X2 |
|
|
| 10 | 11 | |||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| 12 |
|
|
|
|
|
|
| XFMR |
| Fuses |
|
|
|
|
|
|
|
| H1 | H2 |
|
| Optional Summer | ||
|
|
|
|
|
|
|
| (When Req'd) |
| ||
|
| AL2 AL3 | BL3 | Fan Switch | |||||||
|
| ||||||||||
| Factory Wiring |
|
|
| AL1 |
| BL2 | Field Installed | |||
| Transformer Color Code Index |
|
|
|
| ||||||
|
|
| BL1 |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
PRI. | PRI. | XFMR | 120V | SEC. | 24V | SEC. |
|
| Optional Disconnect | ||
VOLT | LEAD | CLRS | LEAD | CLRS. | LEAD | CLRS. |
|
| |||
| H1 | H2 | X1 | X2 | X1 | X2 | Note: Heater requires |
| Switch | ||
| L1 L2 L3 | Field Installed |
| ||||||||
208 | BLK | RED | BLK | WHT | YEL | BLU | Fan Relay for 480V |
| |||
|
|
|
| ||||||||
240 | BLK | ORG | BLK | WHT | YEL | BLU | Motors. (See Figure L) | 3 Phase, |
| ||
|
|
|
|
|
|
|
| 60 HZ Power |
|
C2
T1T2T3 |
| T1T2T3 |
C1 | Contactor | C2 |
Motor
3Ø
Standard Motor Connection
1 2
3
7
9 8
10 11
12
Summer Fan Switch
Transformer Color Code Index
PRI. | PRI. XFMR | 120V SEC. | 24V SEC. | ||||
VOLT. | LEAD | CLRS. | LEAD CLRS. | LEAD | CLRS. | ||
| H1 |
| H2 | X1 | X2 | X1 | X2 |
208 | BLK |
| RED | BLK | WHT | YEL | BLU |
240 | BLK |
| ORG | BLK | WHT | YEL | BLU |
480 | BLK | BLK/RED | BLK | WHT | YEL | BLU |
Optional Thermostat | Elements |
| Elements | ||
|
| ||||
Field Installed |
|
|
|
| |
|
|
| Stage 1 | Fan Relay | Stage 2 |
| C3 |
|
|
|
|
| Cutouts |
|
|
| |
| C2 |
| T1T2T3 |
| T1T2T3 |
|
|
| Contactor | ||
| Contactor | C1 | C2 | ||
| C3 | ||||
|
|
|
|
| |
|
|
|
| Motor |
|
C1 |
|
|
| 3Ø |
|
X1 | X2 |
|
| Fuses | |
|
| Fuses |
| ||
|
|
|
|
| |
| XFMR |
| AL2 AL3 | (When Req'd) | BL3 |
|
|
|
| BL2 | |
|
|
|
|
| |
H1 | H2 |
| AL1 |
| BL1 |
|
|
|
| ||
|
| Optional Disconnect |
|
| |
|
| Switch |
|
| |
| Field Wiring | Field Installed |
|
| |
|
|
| L1L2 L3 |
| |
|
| ||||
|
|
| |||
| Factory Wiring |
| 3 Phase |
| |
|
| For Use With 480V | 60 HZ Power |
| |
|
|
|
| ||
|
|
|
|
Figure K
| Elements |
|
| Elements | |
|
|
| Motor |
| |
|
|
| 3Ø |
| |
| Stage 1 |
|
| Stage 2 | |
|
|
| Fuses |
| |
|
|
|
| ||
| C3 |
|
|
| |
| C2 |
|
| T1 T2 T3 | |
Control Power | T1 T2 T3 | Contactor (Typ.) | |||
C1 | C2 | ||||
(By Others) | |||||
Cutouts |
|
|
| ||
|
|
|
| ||
| C1 |
|
|
| |
Optional Thermostat |
|
| Fuses |
| |
AL2 AL3 | (When Req'd) | BL3 | |||
| |||||
Field Installed | AL1 |
|
| BL1 BL2 | |
|
|
| |||
Field Installed | Optional Disconnect |
| L3 | 3 Phase, | |
Switch |
| L2 | 60 HZ Power | ||
| L1 | ||||
Factory Wiring | Field Installed |
|
|
| |
| |||||
|
|
Figure M
C2 |
|
|
| Optional Thermostat | Elements |
| Elements | |
T1T2T3 |
| T1T2T3 |
|
|
|
| ||
C1 | Contactor | C2 |
| Field Installed |
|
|
| |
|
|
|
| (Single Stage) | Stage 1 | Fan Relay | Stage 2 | |
|
|
|
|
|
| |||
| Motor |
|
|
| C3 |
|
| |
|
|
|
|
|
|
| ||
| 3Ø |
|
|
| C2 |
|
|
|
|
|
|
|
|
|
| T1T2T3 | |
|
|
|
|
|
| T1T2T3 | Contactor | |
Standard Motor Connection |
|
| Contactor | C1 | C2 | |||
|
| C3 | ||||||
|
|
|
|
|
|
|
| |
|
|
| 2 |
| Cutouts |
|
|
|
|
| 1 |
|
|
| Motor |
| |
|
| 3 |
|
|
|
| 3Ø |
|
|
| 7 |
|
|
|
|
| |
|
|
|
|
|
| Fuses | ||
|
| 9 | 8 |
| C4 |
| ||
|
| 10 | 11 | C1 |
| Fuses |
| |
|
| 12 |
|
|
| AL2 AL3 | (When Req'd) | BL3 |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| BL2 |
|
|
|
| Control Power | AL1 |
| BL1 | |
Summer Fan Switch |
|
|
|
| ||||
| (By Others) |
|
|
| ||||
|
|
|
|
| Optional Disconnect |
|
| |
|
|
|
|
| Switch | L1L2 L3 |
| |
|
|
|
|
| Field Installed |
| ||
| Field Installed |
|
| For Use With 480V | 3 Phase |
| ||
|
|
| ||||||
|
| 60 HZ Power |
| |||||
| Factory Wiring |
|
|
|
|
Figure O
Figure L
| Field Wiring |
| Elements |
| Elements | Motor | ||
|
|
|
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
| 3Ø |
| ||
| Factory Wiring |
|
|
|
|
|
| |
|
| Stage 1 |
| Stage 2 |
|
| ||
|
|
|
|
| Fuses | |||
|
|
|
|
|
|
|
| |
| C3 |
|
|
|
|
|
|
|
| C2 |
|
|
|
|
| 1 | 2 |
Control Power |
|
| T1 T2 T3 |
|
| T1 T2 T3 | 3 |
|
(By Others) |
| Cutouts | C1 |
| Contactor | C2 | 7 | 8 |
|
|
|
|
| 9 | |||
| C1 |
|
|
| (Typ.) |
| 10 | 11 |
|
|
|
|
|
|
| 12 |
|
To Elements | To Elements | Optional Thermostat |
|
| Fuses |
| Optional Summer | |
AL2 | AL3 | (When Req'd) | BL3 | Fan Switch | ||||
Stage 1 | Stage 2 |
| ||||||
Motor | Field Installed |
|
|
| BL2 | |||
3Ø |
|
|
|
| Field Installed | |||
|
|
| AL1 |
|
| BL1 | ||
|
|
|
|
|
|
| ||
|
| Note: Heater Requires |
|
|
| Optional Disconnect | ||
|
| Fan Relay For 480V Motors |
|
| Switch | |||
C1 | C2 | (See Fig. O) |
|
| L1 L2 L3 | Field Installed |
| |
Standard Motor |
| 3 Phase, |
|
|
| |||
Connection | 60 HZ Power |
|
|
|
Figure N
Warning - First Stage Of Thermostat Must |
| Elements |
|
| Elements | ||
|
|
|
|
| |||
Be Connected To Terminals C1 & C2 To |
|
|
| Motor |
| ||
Insure That Motor Will Be Energized With |
|
|
|
| |||
|
|
| 3Ø |
| |||
First Stage Heat Operation |
|
|
|
| |||
| Stage 1 |
|
| Stage 2 | |||
|
|
|
|
|
| ||
|
|
|
|
|
| Fuses |
|
|
|
|
|
|
|
| |
| C3 |
| C3 |
|
|
|
|
|
| C2 |
|
|
|
| |
| C2 |
| Cutouts | C1 | Contactor (Typ.) | C2 | |
|
|
|
|
|
|
| |
| C1 | Stage 1 |
|
|
|
|
|
|
|
|
|
|
|
| |
Alternate |
|
|
|
|
| Fuses |
|
1 Stage |
| Stage 2 | C1 |
|
|
| |
Thermostat |
|
|
|
| (When Req'd) |
| |
(by Others) | 2 Stage Thermostat |
|
|
|
|
| |
|
| (By Others) |
|
|
|
|
|
|
|
|
|
|
| Fused Switch |
|
|
|
|
|
|
| (By Others) |
|
Customer Wiring |
| AL1 AL2 AL3 |
|
| BL1 BL2 BL3 | ||
|
|
|
|
| |||
Factory Wiring |
|
| 3 Phase, |
|
| 3 Phase, | |
|
| 60 HZ Power |
| 60 HZ Power |
Figure P
6