GENERAL

NOTICE: Type ARR Thermostats are designed for temperature control service only. Because they do not fail safe, they should not be used for temperature limiting duty.

CAUTION: Users should install adequate back-up controls and safety devices with their electric heating equipment. Where the con- sequences of failure may be severe, back-up controls are essential. Although the safety of the installation is the responsibility of the user, Chromalox will be glad to make equipment recommendations. Principle of Operation — Control action of these thermostats is provided through the principle of liquid volume change. With a variation in temperature, the liquid in the sensing bulb expands or contracts, causing a bellows to actuate the switching mechanism. Note: In Inverse-Action Thermostats, contacts close on tempera- ture rise.

Housing — The control housing and cover assembly is of heavy- gage sheet metal on NEMA-I models.

Moisture resistant (LT) models have housing and cover assembly made of heavy gage cast aluminum.

Power Supply — WARNING: Use on AC only. Thermostat is not DC rated.

Control Range — The following temperature ranges are available:

Fahrenheit

60 to 250 200 to 550

Note: This control does not have an “OFF” position.

Process Temperature Differential — May be minimized by:

1.Make sure control is mounted to vertical surface. (See Step 1, MOUNTING section)

2.Avoid excess cooling capacity.

3.Locate control sensing bulb in optimum position between cool- ing source and work.

Packing Glands — If a sealed or leak-proof connection is required at the point where the capillary enters the oven, tank, pipe or similar equipment, an appropriate packing gland is available as an optional part. (Models CCF-25A, CCF-25D or CCF-25E)

CAUTION: Not for use in hazardous environments as described in National Electrical Code. Failure to comply can result in explosion or fire.

MOUNTING

Note: Do not mount control where it will be subject to vibration, shock, grease, dust, lint or corrosive vapors. Do not mount adja- cent to a large magnetic contactor, as vibration and shock will cause thermostat to interact erratically — resulting in chattering of the contactor.

The air temperature in and around the control enclosure should be kept as near to normal room temperature as possible... never above 150°F.

4.CAUTION —

A.Bending or deforming sensing bulb will alter control cali- bration — requiring recalibration after installation. See CALIBRATION section, page 3. If necessary, Style 9 bulbs can be coiled to 1” I.D. (See Figure 3.)

B.Do not kink capillary tube. The resulting constrictions in fluid flow can destroy control function or broaden temper- ature differential. Minimum capillary tube bending diame- ter is 1/2” I.D. (See Figure 4)

NEMA-I Models

27/16"

37/8"

Mounting Holes

Figure 2

LT Models

Mounting Lugs

57/8" Dia.

5"

5/16" Dia.

(2)

1”

Figure 3

(Sensing Bulb)

Do Not

Bend or Kink

Crimped End

1/2” Rod

Figure 4

(Capillary Tube)

1.Thermostat must be mounted in a vertical position only.

2.Use sheet metal or wood screws through the mounting holes in baseplate to mount control. (See Figure 2)

3.For controlling platen or die temperatures, insert entire sensing bulb into drilled holes selected for snug slip fit.

The longer, more sensitive Style 9 bulbs should be used for controlling air temperatures or pipe line heating.

Note: If material in contact with bulb or capillary is corrosive, a protective well should be used. Protective wells are available as an optional part. Check Factory.

C.Any deformations of bulb or capillary that result in leakage of fluid from control renders control inoperative.

D.Avoid passing control capillary tube through zones whose temperature is in excess of controlled process temperature. Erratic control or destruction of control function may result.

WIRING

CAUTION: Hazard of Electrical Shock. Disconnect all power before wiring or servicing this control. Failure to comply can result in electrical shock or electrocution.

1.Electric wiring to heater must be installed in accordance with local and National Electrical Codes. WARNING: Use cop- per conductors only.

NEMA I Models:

A.Entrance for wiring is provided by two 1/2” conduit holes in end of base plate.

B.Remove knob by lifting knob from shaft. (See Figure 6)

C.Removal of the knob will reveal two mounting screws posi- tioned under the knob. Remove screws and lift off cover. (See Figure 7).

Page 2
Image 2
Chromalox PK425-2 specifications General, Mounting, Wiring

PK425-2 specifications

The Chromalox PK425-2 is an advanced unit in the realm of industrial heating solutions, specifically designed for various heating applications. Known for its precision and reliability, this product is widely utilized in industries ranging from food processing and chemical manufacturing to oil and gas.

One of the standout features of the PK425-2 is its high-performance heating element, which is engineered for excellent thermal efficiency. The device incorporates robust construction materials and cutting-edge design, which work together to optimize heat transfer. This ensures that the desired temperatures are achieved quickly and maintained consistently, crucial for processes that require strict temperature control.

In addition to its heating capabilities, the PK425-2 boasts sophisticated temperature control technology. It is compatible with temperature controllers, allowing users to fine-tune operational settings for specific applications. This versatility enables it to cater to a wide array of processes, from simple to complex heating requirements. The seamless integration of controller systems helps in better monitoring and can lead to significant energy savings.

Safety is another critical aspect of the PK425-2 design. It comes equipped with built-in safety features, including over-temperature protection and safety shutoff mechanisms. These features not only ensure safe operation during high-demand scenarios but also enhance the overall longevity of the unit.

Durability is a hallmark of the PK425-2. The unit is constructed from materials that withstand harsh industrial environments, making it highly durable and resistant to corrosion and wear. This longevity decreases maintenance needs, providing a cost-effective solution for businesses looking to minimize downtime and operational expenses.

Efficiency is a crucial characteristic of the Chromalox PK425-2, resulting in reduced energy consumption without compromising on performance. This not only lowers operational costs but also aligns with modern sustainability goals.

In summary, the Chromalox PK425-2 stands out in the industrial heating market with its combination of high-performance heating elements, advanced temperature control technology, built-in safety features, and premium durability. These characteristics make it a reliable choice for industries requiring consistent and efficient heating solutions, solidifying its reputation as a superior product in its category.