CiscoAironetAccessPointDeploymentGuide 
CiscoSystems
Copyright©2012CiscoSystems,Inc.Allrightsreserved.
Page22of52
Figure28:MetalPinsorPadlocksforAreasofHighVibration
WarehouseandFactory
Warehouseinstallationsareoftendifficultbecauseoftheveryhighceilingsandtheclutterofthe
materialinstorage.Aspartofyoursitesurvey,alwayscheckthecoveragewhenthewarehouseisfully
stocked,sincethematerialinstoragecanchangetheRFcoverageandinterferewithuniformcoverage.
Foraisles,usedirectional(patch)antennasonthewallandshootdowntheaisles.Youcanalsouselow
gainomnidirectionalantennas(suchasdipoles)ontheceilingorunitswithintegratedantennas;high
gainomnidirectionalantennastendtohavemorenulls.(SeeFigure50.)
ThehighertheAPismounted,thefartherthesignalmusttravel.Usepipeandelectricalboxmounting
techniquestolowertheAP(externalandinternalantennamodels)sothatitisclosertousers.(See
Figure29.)