C-17
Cisco UCS C24 Server Installation and Service Guide
OL-26647-01
Appendix C RAID Controller Considerations
RAID Controller Cabling
RAID Controller Cabling
This section includes the following topics:
Cable Routing, page C-17
Cisco UCS C24 Server RAID Cabling Instructions, page C-18

Cable Routing

The RAID controller connectors in this server are shown in Figure C-2. The colored lines indicate the
recommended cable-routing paths from the SAS expander or backplane to the possible controller
locations:
The red line is the cable path to a controller in PCIe riser 1. The cable is routed across the chassis
in clips on the air baffle (not shown). This is the only riser available in single-CPU configurations.
The blue line is the cable path to a controller in PCIe riser 2.
The green line is the cable path to the embedded RAID connectors on the motherboard.
Figure C-2 RAID Controller Cable Routing
285262
Port 1
Port 0
SYS FAN1
SYS FAN2
SYS FAN3
SYS FAN4
CPU 1
CPU 2
PCIe riser 1
PCIe riser 2
PSU 1 (bottom)
PSU 2 (top)

3 5 6

1

2

4

1Drive backplane 4PCIe risers for RAID controller cards
2SAS expander connectors 5Embedded RAID SAS connector
(SCU_PORT_0)
3SCPM mounting cage 6Embedded RAID SAS connector
(SCU_PORT_1)