Cisco Systems Superx Series manual System Management

Models: Superx Series

1 12
Download 12 pages 24.3 Kb
Page 9
Image 9
System Management

System Management

IronView Network Manager (INM)

Web-based Graphical User Interface

Embedded Web Management

Industry Standard Command Line Interface (CLI)

RMON HP OpenView for Sun Solaris

HP-UX, IBM’s AIX, and Windows NT

Virtual Cable Tester

Repeater MIB

Element Security Options

Authentication, Authorization, and Accounting (AAA)

RADIUS

Secure Shell (SSHv2)

Secure Copy (SCP)

TACACS/TACACS+

Username/Password (Challenge and Response)

Bi-level Access Mode (Standard and EXEC Level)

Protection for Denial of Service attacks, such as TCP SYN or Smurf Attacks

Physical Design

ETSI ETS 300 119-4, Engineering Requirements for Sub-racks in misc. racks and cabinets

ANSI/EIA-310-D, Cabinets, Racks, Panels, and Associated Equipment

Dimensions

FastIron SuperX and

10.4” (H) x 17.5” (W) x 17.3” (D)

FastIron SX 800

26.3 cm (H) x 44.5 cm (W) x 43.8 cm (D)

 

FastIron SX 1600

24.5” (H) x 17.5” (W) x 17.3” (D)

 

62.2 cm (H) x 44.5 cm (W) x 43.8 cm (D)

Weight (Fully Loaded)

 

FastIron SuperX and

70 lbs (31 kg)

FastIron SX 800

 

FastIron SX 1600

196 lbs (88.6 kg)

Environmental

 

Operating temperature: 0ºC to 40ºC (32ºF to 104ºF)

Relative humidity: 5 to 90%, @40ºC (104ºF, non condensing)

Operating altitude: 6600 ft (2,000 m)

Storage temperature: -25ºC to 70ºC (-13ºF to 158ºF)

Storage humidity: 95% maximum relative humidity, non-condensing

Storage altitude: 15,000 ft (4,500 m) maximum

MTBF

Chassis

• SuperX Chassis, Fan Tray, 1 P/S: 269,386 hrs

 

• SX 800 Chassis, Fan Tray, 1 P/S: 142,786 hrs

 

• SX 800 Chassis, Fan Tray, 2 P/S: 230,584 hrs

 

• SX1600 Chassis, Fan Tray, 2 P/S: 99,908 hrs

 

• SX1600 Chassis, Fan Tray, 4 P/S: 213,865 hrs

Management Modules

• IPv4 Management Module with no optics:

 

287,664 hrs

 

• IPv4 Management Module, Zero ports:

 

534,522 hrs

 

• IPv4 Management Module, 2x10-GbE ports:

 

269,436 hrs

 

• IPv6 Management Module, 256MB SDRAM,

 

no optics: 292,557 hrs

 

• IPv6 Management Module, 512MB SDRAM,

 

no optics: 287,425 hrs

 

• IPv6 Management Module, 2x10GbE,

 

no optics: 304,109 hrs

Interface modules (IPv4

24-port 10/100/1000 Copper Module:

and IPv6 versions)

352,103 hrs

 

24-port SFP Module: 348,204 hrs

 

2-port 10-GbE Module: 464,938 hrs

Power Requirements

System Power Supply

-40-60 VDC Consumption (Amps): 36A

(SX-ACPWR, SX-DCPWR)

• 100 – 120 VAC Consumption (Amps): 14.3A

 

• 200 – 240 VAC Consumption (Amps): 7.2A

 

• AC Frequency: 50 – 60Hz

 

• Max BTU: 4874 BTU/Hr

 

• Max Watts (Output): 1200W

 

• Max Watts (Input): 1428W

1250W PoE Power Supply

• 100 – 120 VAC Consumption (Amps): 14A

 

• 200 – 240 VAC Consumption (Amps): 7A

 

• AC Frequency: 50 – 60Hz

 

• Max BTU: 4736 BTU/Hr

 

• Max Watts (Output): 1250W

 

• Max Watts (Input): 1388W

2500W PoE Power Supply

• 200 – 240 VAC Consumption (Amps): 14A

(SX-ACPWR-2500-POE)

• AC Frequency: 50 – 60Hz

 

• Max BTU: 9471 BTU/Hr

 

• Max Watts (Output): 2500W

 

• Max Watts (Input): 2775W

Safety Certifications

CAN/CSA-C22.2 No. 60950-1-03

Information Technology Equipment

Safety—Part 1: General Requirement

UL 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

EN 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

IEC 60950-1, Information Technology Equipment—Safety— Part 1: General Requirement

EN 60825-1, Safety of Laser Products. Equipment Classification,

Requirements and User Guide

EN 60825-2, Safety of Laser Products, Safety of Optical Fibre Communications Systems

Environmental Regulatory Compliance

RoHS Compliant (5 of 6)

WEEE compliant

Electromagnetic Emission Certifications

ICES-003, Electromagnetic Emission

FCC Class A

EN 55022/CISPR 22 Class A

VCCI Class A

EN 61000-3-2, Power Line Harmonics

EN 61000-3-3, Voltage Fluctuation and Flicker

EN 61000-6-3, Electromagnetic Compatibility

AS/NZS CISPR 22, Electromagnetic Compatibility

Immunity

EN 61000-6-1, Electromagnetic Compatibility, Generic Standard

EN 55024, Immunity Characteristics Supersedes:

EN 61000-4-2, ESD

EN 61000-4-3, Radiated, Radio Frequency, Electromagnetic Field

EN 61000-4-4, Electrical Fast Transient

EN 61000-4-5, Surge

EN 61000-4-6, Conducted Disturbances Induced by Radio

Frequency Fields

EN 61000-4-8, Power Frequency Magnetic Field

EN 61000-4-11, Power Frequency Magnetic Field

Mounting Options

• 19” Universal EIA (Telco) Rack or Tabletop

Page 9
Image 9
Cisco Systems Superx Series manual System Management