3

Steam connection

Machines with steam heating must have a steam valve between the steam installation and the machine.

With direct steam injection into the machine

1.Steam pipe

2.Steam cut-off valve 3/8"

3.Pipe coupling 3/8"

4.Steam filter 3/8"

5.Magnetic steam valve 3/8"

6.Curve MF 3/8"

7.Steam hose with appropriate pipe coupling 3/8"

Added parts for steam heating with heat exchanger

3. Double pipe coupling 1/2"

9.Condensation accumulator with filter 1/2"

10.Conical coupling MM 1/2"

11.Single window 1/2"

12.One-way valve 1/2"

M = inner wire, F = outer wire

The manufacturer is not responsible for damage or accidents caused by not following the installation instructions!