3

Water drain

The machine is equipped with a drain valve (HF150-185) with 2" outer diameter (50mm) (HF234) 3" outer diameter (80 mm). This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.

The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 160L/min. per machine.

It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation.

When the main drain has not been sufficiently deodorized, eve- ry machine should be installed seperately with a deodorizer.

Electrical Connection

Remove the cover plate at the back of the machine. (See dimen- sions (E)).

Connect the power cable to the connectors.

220V 3AC

220V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”.

The green/yellow grounding clamp has to be connected to the grounding wire “PE”.

380 V 3AC + N

380 V 3 phase (3AC + N) has to be connected to the connectors “L1,L2,L3”, the blue neutral to the “N” connector.

The green/yellow grounding clamp has to be connected to the grounding wire “PE”.

After connection, check the spin direction. The cylinder must spin in the direction of the arrow, showed on the sticker on the door window (clockwise).

A wrong spin direction can damage the motor, and can also cause water to spurt from the soap dispenser.

Power of the breaker plugs:

machine with steam heating or boiler fed machines without additional electrical heating

220V 3AC 380V 3AC + N

16 A

16 A

machine with electrical heating

 

220V 3AC 380V 3AC + N

9kw

25A

16A

12 kW

40 A

20 A

15 kW

50 A

25 A

18 kW

50 A

32 A

21 kW

----

40 A

24 kW

----

40 A