3.4 Setting DIP Switch

DIP switch is provided only for serial interface specification.

The DIP switch is located at the bottom of the paper holder. To set the DIP switch open the paper cover and remove the paper.

ON

OFF

18

Switch No.

Function

ON

 

OFF

Initial

 

Settings

 

 

 

 

 

 

1

Communication condition

DIP switch setting

Internal memory

ON

 

setting method

 

 

setting

 

2

Hand shake

XON/XOFF

DTR/DSR

OFF

3

Bit length

7 bits

8 bits

OFF

4

Parity check

With parity

None

OFF

5

Parity selection

Even parity

Odd parity

OFF

6

 

 

 

 

 

OFF

Baud rate selection

See Table below.

 

 

 

7

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

8

Reserved

Fixed

OFF

Selecting baud rate

 

 

 

 

 

Baud Rate (bps)

 

Switch No.

6

 

7

 

 

2400

OFF

 

OFF

4800

ON

 

OFF

9600

OFF

 

ON

19200

ON

 

ON

38400 bps can also be selected by a command.

— 18 —